SBAS500B june 2022 – august 2023 ADC32RF54 , ADC32RF55
PRODUCTION DATA
After the initial power up, both hardware and software reset are required.
ADDRESS | DATA | DESCRIPTION |
---|---|---|
0x00 | 0x01 | Software set and reset |
0x00 | 0x00 | |
0x01 | 0x00 | |
0x09 | 0x20 | These two resets are staggered in order to minimize strain on external power supply. |
0x09 | 0x80 | |
0x09 | 0x00 | |
0x08 | 0x01 | Internal memory reset (set and reset) |
0x08 | 0x00 | |
0x05 | 0x40 | Select ANALOG page |
0x47 | 0x80 | Analog reset (set and reset) |
0x47 | 0x00 |