SBASAU9 October   2024 ADC3908D025 , ADC3908D065 , ADC3908D125 , ADC3908S025 , ADC3908S065 , ADC3908S125

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics - Power Consumption
    6. 6.6  Electrical Characteristics - DC Specifications
    7. 6.7  Electrical Characteristics - AC Specifications (25 MSPS)
    8. 6.8  Electrical Characteristics - AC Specifications (65 MSPS)
    9. 6.9  Electrical Characteristics - AC Specifications (125 MSPS)
    10. 6.10 Timing Requirements
    11. 6.11 Output Interface Timing Diagram
    12. 6.12 Typical Characteristics: 25MSPS
    13. 6.13 Typical Characteristics - 65MSPS
    14. 6.14 Typical Characteristics - 125MSPS
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Analog Input
        1. 7.3.1.1 Single Ended Input
        2. 7.3.1.2 Differential Input
        3. 7.3.1.3 Analog Input Bandwidth
      2. 7.3.2 Sampling Clock Input
      3. 7.3.3 Digital Interface
        1. 7.3.3.1 Test Pattern
        2. 7.3.3.2 Interface Configuration using Pin Control
    4. 7.4 Device Functional Modes
      1. 7.4.1 Normal Operation
      2. 7.4.2 Power Down
  9. Application Information Disclaimer
    1. 8.1 Typical Application
      1. 8.1.1 Design Requirements
      2. 8.1.2 Detailed Design Procedure
        1. 8.1.2.1 Input Signal Path
        2. 8.1.2.2 Sampling Clock
      3. 8.1.3 Application Curves
    2. 8.2 Initialization Set Up
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Receiving Notification of Documentation Updates
    2. 9.2 Support Resources
    3. 9.3 Trademarks
    4. 9.4 Electrostatic Discharge Caution
    5. 9.5 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Recommended Operating Conditions

over operating free-air temperature range (unless otherwise noted)
MIN NOM MAX UNIT
Supply voltage range  Supply voltage range 1.8v AVDD(1) 1.7 1.8 1.9 V
Supply voltage range  IOVDD(1) 1.7 1.8 1.9 V
Supply voltage range  Supply voltage range 3.3v IOVDD(1) 3.2 3.3 3.4 V
TA Operating free-air temperature –40 105 °C
TJ Operating junction temperature 115(2) °C
Measured to GND.
Prolonged use above this junction temperature may increase the device failure-in-time (FIT) rate.