SBAS740B October 2015 – May 2020 ADS1118-Q1
PRODUCTION DATA.
Table 8 shows the design parameters for this application.
DESIGN PARAMETER | VALUE |
---|---|
Supply voltage | 3.3 V |
Full-scale range | ±0.256 V |
Update rate | ≥ 100 readings per second |
Thermocouple type | K |
Temperature measurement range | –200°C to +1250°C |
Measurement accuracy at TA = 25°C(1) | ±1.2°C |