SBAS683B August 2014 – May 2020 ADS1120-Q1
PRODUCTION DATA.
The power-supply ramp rate must be monotonic and slower than 1 V per 50 µs, as shown in Figure 83, to ensure proper device power-up over the entire temperature range.