SBAS683B August 2014 – May 2020 ADS1120-Q1
PRODUCTION DATA.
The power supplies can be sequenced in any order but in no case must any analog or digital inputs exceed the respective analog or digital power-supply voltage limits. Wait approximately 50 µs after all power supplies are stabilized before communicating with the device to allow the power-up reset process to complete.