SBAS784A January 2019 – May 2019 ADS1260-Q1 , ADS1261-Q1
PRODUCTION DATA.
The RESET command resets ADC operation and resets the registers to default values. See the Reset by Command section for details. Table 18 shows the RESET command byte sequence.
DIRECTION | BYTE 1 | BYTE 2 | BYTE 3 | BYTE 4 |
---|---|---|---|---|
No CRC mode | ||||
DIN | 06h | Arbitrary | ||
DOUT/DRDY | FFh | Echo byte 1 | ||
CRC mode | ||||
DIN | 06h | Arbitrary | CRC-2 | 00H |
DOUT/DRDY | FFh | Echo byte 1 | Echo byte 2 | Out CRC-2 |