SBAS691B March 2016 – October 2018 ADS1282-SP
PRODUCTION DATA.
The conversion data can be scaled for offset and gain before yielding the final output code. As shown in Figure 74, the output of the digital filter is first subtracted by the offset register (OFC) and then multiplied by the full-scale register (FSC). Equation 14 shows the scaling:
The values of the offset and full-scale registers are set by writing to them directly, or they are set automatically by calibration commands.
The offset and full-scale calibrations apply to specific PGA settings. When the PGA changes, the contents of these registers may have to be recalculated. Calibration is bypassed in the sinc filter mode.