SBAS559A May   2022  – December 2022 ADS1285

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements: 1.65 V ≤ IOVDD ≤ 1.95 V and 2.7 V ≤ IOVDD ≤ 3.6 V
    7. 6.7 Switching Characteristics: 1.65V ≤ IOVDD ≤ 1.95V and 2.7 V ≤ IOVDD ≤ 3.6 V
    8. 6.8 Timing Diagrams
    9. 6.9 Typical Characteristics
  7. Parameter Measurement Information
    1. 7.1 Noise Performance
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Analog Input
      2. 8.3.2 PGA and Buffer
        1. 8.3.2.1 Programmable Gain Amplifier (PGA)
        2. 8.3.2.2 Buffer Operation (PGA Bypass)
      3. 8.3.3 Voltage Reference Input
      4. 8.3.4 IOVDD Power Supply
      5. 8.3.5 Modulator
        1. 8.3.5.1 Modulator Overdrive
      6. 8.3.6 Digital Filter
        1. 8.3.6.1 Sinc Filter Section
        2. 8.3.6.2 FIR Filter Section
        3. 8.3.6.3 Group Delay and Step Response
          1. 8.3.6.3.1 Linear Phase Response
          2. 8.3.6.3.2 Minimum Phase Response
        4. 8.3.6.4 HPF Stage
      7. 8.3.7 Clock Input
      8. 8.3.8 GPIO
    4. 8.4 Device Functional Modes
      1. 8.4.1 Power Modes
      2. 8.4.2 Power-Down Mode
      3. 8.4.3 Reset
      4. 8.4.4 Synchronization
        1. 8.4.4.1 Pulse-Sync Mode
        2. 8.4.4.2 Continuous-Sync Mode
      5. 8.4.5 Sample Rate Converter
      6. 8.4.6 Offset and Gain Calibration
        1. 8.4.6.1 OFFSET Register
        2. 8.4.6.2 GAIN Register
        3. 8.4.6.3 Calibration Procedure
    5. 8.5 Programming
      1. 8.5.1 Serial Interface
        1. 8.5.1.1 Chip Select (CS)
        2. 8.5.1.2 Serial Clock (SCLK)
        3. 8.5.1.3 Data Input (DIN)
        4. 8.5.1.4 Data Output (DOUT)
        5. 8.5.1.5 Data Ready (DRDY)
      2. 8.5.2 Conversion Data Format
      3. 8.5.3 Commands
        1. 8.5.3.1  Single Byte Command
        2. 8.5.3.2  WAKEUP: Wake Command
        3. 8.5.3.3  STANDBY: Software Power-Down Command
        4. 8.5.3.4  SYNC: Synchronize Command
        5. 8.5.3.5  RESET: Reset Command
        6. 8.5.3.6  Read Data Direct
        7. 8.5.3.7  RDATA: Read Conversion Data Command
        8. 8.5.3.8  RREG: Read Register Command
        9. 8.5.3.9  WREG: Write Register Command
        10. 8.5.3.10 OFSCAL: Offset Calibration Command
        11. 8.5.3.11 GANCAL: Gain Calibration Command
    6. 8.6 Register Map
      1. 8.6.1 Register Descriptions
        1. 8.6.1.1 ID/SYNC: Device ID, SYNC Register (Address = 00h) [Reset = xxxx0000b]
        2. 8.6.1.2 CONFIG0: Configuration Register 0 (Address = 01h) [Reset = 12h]
        3. 8.6.1.3 CONFIG1: Configuration Register 1 (Address = 02h) [Reset = 00h]
        4. 8.6.1.4 HPF0, HPF1: High-Pass Filter Registers (Address = 03h, 04h) [Reset = 32h, 03h]
        5. 8.6.1.5 OFFSET0, OFFSET1, OFFSET2: Offset Calibration Registers (Address = 05h, 06h, 07h) [Reset = 00h, 00h, 00h]
        6. 8.6.1.6 GAIN0, GAIN1, GAIN2: Gain Calibration Registers (Address = 08h, 09h, 0Ah) [Reset = 00h, 00h, 40h]
        7. 8.6.1.7 GPIO: Digital Input/Output Register (Address = 0Bh) [Reset = 000xx000b]
        8. 8.6.1.8 SRC0, SRC1: Sample Rate Converter Registers (Address = 0Ch, 0Dh) [Reset = 00h, 80h]
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
    3. 9.3 Power Supply Recommendations
      1. 9.3.1 Analog Power Supplies
      2. 9.3.2 Digital Power Supply
      3. 9.3.3 Grounds
      4. 9.3.4 Thermal Pad
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  10. 10Device and Documentation Support
    1. 10.1 Receiving Notification of Documentation Updates
    2. 10.2 Support Resources
    3. 10.3 Trademarks
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 Glossary
  11. 11Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Description

The ADS1285 is a 32-bit, low-power, analog-to-digital converter (ADC), with a programmable gain amplifier (PGA) and a finite impulse response (FIR) filter. The ADC is designed for the demanding needs of seismology equipment requiring low-noise precision digitization and extended battery run time.

The low-noise PGA allows direct connection of geophones and transformer-coupled hydrophones without the need of an external amplifier.

The ADC incorporates a high-resolution, delta-sigma (ΔΣ) modulator and a FIR filter with programmable phase response. The high-pass filter removes dc and low-frequency content from the signal. Clock frequency error is compensated by the sample rate converter with 7-ppb resolution.

Choice of power modes optimize dynamic range verses power consumption. Power consumption is further reduced by PGA bypass operation.

The ADC is available in a compact 5-mm × 5-mm VQFN package and is fully specified over the –40°C to +85°C ambient temperature range.

Package Information(1)
PART NUMBER PACKAGE BODY SIZE (NOM)
ADS1285 RHB (VQFN, 32) 5.00 mm × 5.00 mm
For all available packages, see the package option addendum at the end of the data sheet.
Functional Block Diagram