SBAS705B June 2015 – April 2020 ADS131E08S
PRODUCTION DATA.
This register configures the fault detection operation.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
COMP_TH[2:0] | 0 | 0 | 0 | 0 | 0 | ||
R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h |
LEGEND: R/W = Read/Write; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7-5 | COMP_TH[2:0] | R/W | 0h | Fault detect comparator threshold.
These bits determine the fault detect comparator threshold level setting. See the Input Out-of-Range Detection section for a detailed description. Comparator high-side threshold. 000 = 95% 001 = 92.5% 010 = 90% 011 = 87.5% 100 = 85% 101 = 80% 110 = 75% 111 = 70% Comparator low-side threshold. 000 = 5% 001 = 7.5% 010 = 10% 011 = 12.5% 100 = 15% 101 = 20% 110 = 25% 111 = 30% |
4-0 | Reserved | R/W | 00h | Reserved.
Must be set to 0. This bit reads low. |