SBAS891B November 2017 – September 2022 ADS7142-Q1
PRODUCTION DATA
Figure 7-2 shows a simplified block diagram showing a two-channel, single-ended configuration. Set the CH0_CH1_IP_CFG bits = 00b or 11b to select this configuration. This configuration is also the default for the device after power up. In this configuration, CS2 always samples the GND pin and CS1 samples the input signal provided on channel 0 (AINP/AIN0) or channel 1 (AINM/AIN1) based on the channel selection. Each analog input channel can accept input signals in the range 0 V to AVDD V.
On power-up, the device wakes up in manual mode with two-channel, single-ended configuration and samples CH0 only. This configuration can also be set by setting OPMODE_SEL to 000b or 001b,
The device can be configured to sample either CH0 or CH1 or both channels by setting bits in the AUTO_SEQ_CHEN register to select the channels.