6.8 Timing Requirements: Parallel Data Read Operation,
CS and
RD Tied Together
minimum and maximum specifications are at TA = –40°C to +125°C, typical
specifications are at TA = 25°C; AVDD = 5 V, 2.3 V ≤ DVDD ≤ 5.25 V,
VREF = 2.5 V (internal), load on DB[15:0] and FRSTDATA = 20 pF,
VIL and VIH at specified limits, and
fSAMPLE = 500 kSPS (unless otherwise noted) (see Figure 6-3)
MIN
NOM
MAX
UNIT
tPH_CS,
tPH_RD
CS and RD high
time
15
ns
tPL_CS,
tPL_RD
CS and RD low
time
15
ns
tHT_RDDB,
tHT_CSDB
Hold time: RD and CS
rising edge to DB[15:0] invalid