SBAS779B December 2016 – March 2021 ADS8671 , ADS8675
PRODUCTION DATA
MIN | TYP | MAX | UNIT | ||
---|---|---|---|---|---|
TIMING REQUIREMENTS | |||||
twl_RST | Pulse duration: RST high | 100 | ns | ||
TIMING SPECIFICATIONS | |||||
tD_RST_POR | Delay time for POR reset: RST rising to RVS rising | 20 | ms | ||
tD_RST_APP | Delay time for application reset: RST rising to CONVST/CS rising | 1 | µs | ||
tNAP_WKUP | Wake-up time: NAP mode | 20 | µs | ||
tPWRUP | Power-up time: PD mode | 20 | ms |