SBAS633E February 2016 – August 2022 ADS8681 , ADS8685 , ADS8689
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
In ACQ state, the device acquires the analog input signal. The device enters ACQ state on power-up, after any asynchronous reset, or after the end of every conversion.
The falling edge of the RST falling edge takes the device from an ACQ state to a RESET state. A rising edge of the CONVST/CS signal takes the device from ACQ state to a CONV state.
The device offers a low-power NAP mode to reduce power consumption in the ACQ state; see the Section 8.3.2.1 section for more details on NAP mode.