4 Revision History
Changes from * Revision (November 2016) to A Revision
-
Changed SPI Interface Clock at 1 MSPS tableGo
-
Changed DVDD specified throughput value in the Recommended Operating Conditions from 3.6 V to 5.5 VGo
-
Changed maximum value for DVDD range in Electrical Characteristics, Timing Requirements, and Switching Characteristics from 3.6 V to 5.5 VGo
-
Added TA = 25°C to reference buffer offset voltage test condition in Electrical Characteristics tableGo
-
Changed input offset thermal drift typ value from 10 to 1Go
-
Added fIN = 2 kHz test condition to SFDR in Electrical Characteristics table Go
-
Changed DAQ Circuit With FDA Input Driver and Single-Ended or Differential Input section for clarityGo