SBASAQ6 April 2024 ADS9813
ADVANCE INFORMATION
As shown in Table 6-7, initialize the ADS9813 with a sequence of register writes after device power-up or reset. Connect a free-running sampling clock to the ADC before executing the initialization sequence. The ADS9813 registers are initialized with the default value after the initialization sequence is complete.
STEP NUMBER | REGISTER | COMMENT | ||
---|---|---|---|---|
BANK | ADDRESS | VALUE[15:0] | ||
1 | 0 | 0x03 | 0x0000 | Select register bank 0 |
2 | 0 | 0x00 | 0x0004 | |
3 | 0 | 0x04 | 0x000B | INIT_1 configured |
4 | 0 | 0x03 | 0x0010 | Select register bank 2 |
5 | 2 | 0x22 | 0x0079 | INIT_2 configured |
6 | 2 | 0x23 | 0xE000 | INIT_3 configured |
7 | 2 | 0x26 | 0x0040 | INIT_4 configured and device initialized |
8 | 0 | 0x03 | 0x0002 | Select register bank 1 |
9 | 1 | 0x0D | 0x0080 | Gain error calibration enabled |
As shown in ADS9813 User-Configuration, change the default settings of the ADS9813 for the user-defined configuration. Changes to the analog inputs changes the analog input range, bandwidth, and common-mode voltage range. Changes to the data interface change the number of output lanes (either single or double data rate).
STEP | REGISTER | COMMENT | ||
---|---|---|---|---|
BANK | ADDRESS | VALUE[15:0] | ||
1 | 1 | 0xC1 | User defined | Configure data interface and select internal or external reference |
2 | 1 | 0xC2 and 0xC3 | User defined | Select analog input ranges, see Table 6-1 |
3 | 1 | 0xC0 | User defined | Select analog input bandwidth, see Table 6-2 |
4 | 1 | 0xC4 and 0xC5 | User defined | Select common-mode range for analog inputs, see Table 6-3 and Table 6-4 |