SBASB81 December 2024 AFE5401-EP
PRODUCTION DATA
In this mode, the DECIMATE_2_EN and FILT_EN register bits must be set, and the filter coefficients should be configured. Figure 7-15 shows typical filter response in decimate-by-2 mode for the filter coefficient of set 1 (default). Note that the output data rate is reduced by a factor of 2 as compared to default mode for the given clock input frequency.