SLLS103P December   1990  – March 2024 AM26C31

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics: AM26C31C and AM26C31I
    6. 5.6 Electrical Characteristics: AM26C31Q and AM26C31M
    7. 5.7 Switching Characteristics: AM26C31C and AM26C31I
    8. 5.8 Switching Characteristics: AM26C31Q and AM26C31M
    9. 5.9 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagrams
    3. 7.3 Feature Description
      1. 7.3.1 Active-High and Active-Low
      2. 7.3.2 Operates From a Single 5V Supply
    4. 7.4 Device Functional Modes
  9. Application Information Disclaimer
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Receiving Notification of Documentation Updates
    2. 9.2 Support Resources
    3. 9.3 Trademarks
    4. 9.4 Electrostatic Discharge Caution
    5. 9.5 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Switching Characteristics: AM26C31Q and AM26C31M

over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETERTEST CONDITIONSMINTYP(1)MAXUNIT
tPLHPropagation delay time, low-to-high-level outputS1 is open, see Figure 6-2712ns
tPHLPropagation delay time, high-to-low-level output6.512
tsk(p)Pulse skew time (|tPLH – tPHL|)S1 is open, see Figure 6-20.54ns
tr(OD), tf(OD)Differential output rise and fall timesS1 is open, see Figure 6-3512ns
tPZHOutput enable time to high levelS1 is closed, see Figure 6-41019ns
tPZLOutput enable time to low level1019
tPHZOutput disable time from high levelS1 is closed, see Figure 6-4716ns
tPLZOutput disable time from low level716
CpdPower dissipation capacitance (each driver)(2)S1 is open, see Figure 6-2100pF
All typical values are at VCC = 5V and TA = 25°C.
Cpd is used to estimate the switching losses according to PD = Cpd × VCC2 × f, where f is the switching frequency.