SBAS734C March   2017  – Janaury 2020 AMC1306E05 , AMC1306E25 , AMC1306M05 , AMC1306M25

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
    1.     Device Images
      1.      Simplified Schematic
  4. Revision History
  5. Device Comparison Table
  6. Pin Configuration and Functions
    1.     Pin Functions
  7. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  Recommended Operating Conditions
    4. 7.4  Thermal Information
    5. 7.5  Power Ratings
    6. 7.6  Insulation Specifications
    7. 7.7  Safety-Related Certifications
    8. 7.8  Safety Limiting Values
    9. 7.9  Electrical Characteristics: AMC1306x05
    10. 7.10 Electrical Characteristics: AMC1306x25
    11. 7.11 Switching Characteristics
    12. 7.12 Insulation Characteristics Curves
    13. 7.13 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Analog Input
      2. 8.3.2 Modulator
      3. 8.3.3 Isolation Channel Signal Transmission
      4. 8.3.4 Digital Output
      5. 8.3.5 Manchester Coding Feature
    4. 8.4 Device Functional Modes
      1. 8.4.1 Fail-Safe Output
      2. 8.4.2 Output Behavior in Case of a Full-Scale Input
  9. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Digital Filter Usage
    2. 9.2 Typical Applications
      1. 9.2.1 Frequency Inverter Application
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
        3. 9.2.1.3 Application Curve
      2. 9.2.2 Isolated Voltage Sensing
        1. 9.2.2.1 Design Requirements
        2. 9.2.2.2 Detailed Design Procedure
        3. 9.2.2.3 Application Curve
      3. 9.2.3 What To Do and What Not To Do
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Device Support
      1. 12.1.1 Device Nomenclature
        1. 12.1.1.1 Isolation Glossary
    2. 12.2 Documentation Support
      1. 12.2.1 Related Documentation
    3. 12.3 Related Links
    4. 12.4 Receiving Notification of Documentation Updates
    5. 12.5 Community Resources
    6. 12.6 Trademarks
    7. 12.7 Electrostatic Discharge Caution
    8. 12.8 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DWV|8
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Revision History

Changes from B Revision (June 2018) to C Revision

  • Changed Safety-related certifications bullet in Features section: changed VDE certification revision from DIN V VDE V 0884-10 (VDE V 0884-11) to DIN VDE V 0884-11 and changed IEC 60950-1, and IEC 60065 to IEC 62368-1Go
  • Changed DIN V VDE V to DIN VDE V in Description sectionGo
  • Changed CLR and CPG values from ≥ 9 mm to ≥ 8.5 mm in Insulation Specifications tableGo
  • Changed Insulation Specifications table header row from DIN V VDE V 0884-11 (VDE V 0884-11): 2017-01 to DIN VDE V 0884-11: 2017-01Go
  • Changed VDE certification details in Safety-Related Certifications tableGo
  • Changed Safety Limiting Values table format as per current standardGo
  • Changed free air to ambient in condition statement of Switching Characteristics tableGo
  • Changed 6.05 dB to 6.02 dB in Equation 3Go
  • Changed input common-mode voltage from 2 V to 1.9 V for consistency with Input Bias Current vs Common-Mode Input Voltage figure in What To Do and What Not To Do sectionGo
  • Changed VINx to AINx in Layout Guidelines sectionGo
  • Changed Recommended Layout of the AMC1306x figure to include connection to the shunt resistor and input filter componentsGo

Changes from A Revision (July 2017) to B Revision

  • Changed Reinforced Isolation Capacitor Lifetime Projection figure Go

Changes from * Revision (March 2017) to A Revision

  • Released AMC1306E05 and AMC1306M05 to productionGo
  • Added ±50 µV to first DC Performance sub-bullet to reflect the AMC1306x05 devicesGo
  • Changed standard deviation from 0884-10 to 0884-11 in first Safety-Related Certifications sub-bulletGo
  • Changed VPEAK from 8000 to 7000 and standard deviation from 0884-10 to 0884-11 in first paragraph of Description section Go
  • Deleted Status column from Device Comparison TableGo
  • Changed standard deviation from 0884-10 to 0884-11 in DIN V VDE V 0884-11 section of Insulation Specifications tableGo
  • Changed standard deviation from 0884-10 to 0884-11 in Safety-Related Certifications tableGo
  • Changed prevent to minimize in condition statement of Safety Limiting Values tableGo
  • Added Electrical Characteristics: AMC1306x05 table Go
  • Changed test conditions of Analog Inputs test conditions from (AINP – AINN) / 2 to AGND to (AINP + AINN) / 2 to AGND to include all possible conditionsGo
  • Changed IIB test condition from Inputs shorted to AGND to AINP = AINN = AGND, IIB = IIBP + IIBNGo
  • Added AINP = AINN = AGND to EO parameter test conditions Go
  • Changed minus sign to plus or minus sign in typical specification of EG parameter Go
  • Changed 10% to 90% to 90% to 10% in test conditions of tf parameter Go
  • Added AMC1306x05 devices to Typical Characteristics section Go