SPRS971D August 2016 – March 2020 AMIC110
PRODUCTION DATA.
Refer to the PDF data sheet for device specific package drawings
NO. | PARAMETER | MIN | MAX | UNIT | ||
---|---|---|---|---|---|---|
1 | tw(GPO) | Pulse width, GPO | 2 × P(1) | ns | ||
3 | tsk(GPO) | Internal skew between GPO[n:0] signals(2) | PRU0 | 1.00 | ns | |
PRU1 | 5.00 |