NO. | MIN | MAX | UNIT | ||
---|---|---|---|---|---|
1 | tc(CLOCKIN) | Cycle time, CLOCKIN | 20.00 | ns | |
2 | tw(CLOCKIN_L) | Pulse duration, CLOCKIN low | 10.00 | ns | |
3 | tw(CLOCKIN_H) | Pulse duration, CLOCKIN high | 10.00 | ns | |
4 | tr(CLOCKIN) | Rising time, CLOCKIN | 1.00 | 3.00 | ns |
5 | tf(CLOCKIN) | Falling time, CLOCKIN | 1.00 | 3.00 | ns |
6 | tsu(DATAIN-CLOCKIN) | Setup time, DATAIN valid before CLOCKIN | 4.00 | ns | |
7 | th(CLOCKIN-DATAIN) | Hold time, DATAIN valid after CLOCKIN | 0 | ns | |
8 | tr(DATAIN) | Rising time, DATAIN | 1.00 | 3.00 | ns |
tf(DATAIN) | Falling time, DATAIN | 1.00 | 3.00 |