SLUSFR2 November 2024 BQ21088
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
The input current limit can be controlled through I2C by selecting the ILIM bits.
If the ILIM clamp is active, ILIM_ACTIVE_STAT bit is set.
The MASK_ILIM will prevent interrupt from being issued but does not override the ILIM behavior itself. ILIM value can be programmed dynamically through the I2C by the host.