SLUSDF7A January 2020 ā February 2022 BQ25616
PRODUCTION DATA
The device terminates a charge cycle when the battery voltage is above the recharge threshold, and the current is below termination current. After the charging cycle has completed, the BATFET turns off. STAT is asserted HIGH to indicate charging is done. The converter keeps running to power the system, and BATFET can turn on again to engage Section 9.3.6.3.
If the device is in IINDPM/VINDPM regulation, or thermal regulation, the actual charging current will be less than the termination value. In this case, termination is temporarily disabled.
When termination occurs, the STAT pin goes HIGH.
The top-off timer is reset at one of the following conditions: