SLUSD20B july   2018  – april 2023 BQ25710

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Description (continued)
  6. Device Comparison Table
  7. Pin Configuration and Functions
  8. Specifications
    1. 8.1 Absolute Maximum Ratings
    2. 8.2 ESD Ratings
    3. 8.3 Recommended Operating Conditions
    4. 8.4 Thermal Information
    5. 8.5 Electrical Characteristics
    6. 8.6 Timing Requirements
    7. 8.7 Typical Characteristics
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  Power-Up from Battery Without DC Source
      2. 9.3.2  Vmin Active Protection (VAP) when Battery only Mode
      3. 9.3.3  Power-Up From DC Source
        1. 9.3.3.1 CHRG_OK Indicator
        2. 9.3.3.2 Input Voltage and Current Limit Setup
        3. 9.3.3.3 Battery Cell Configuration
        4. 9.3.3.4 Device Hi-Z State
      4. 9.3.4  USB On-The-Go (OTG)
      5. 9.3.5  Converter Operation
        1. 9.3.5.1 Inductance Detection Through IADPT Pin
        2. 9.3.5.2 Continuous Conduction Mode (CCM)
        3. 9.3.5.3 Pulse Frequency Modulation (PFM)
      6. 9.3.6  Current and Power Monitor
        1. 9.3.6.1 High-Accuracy Current Sense Amplifier (IADPT and IBAT)
        2. 9.3.6.2 High-Accuracy Power Sense Amplifier (PSYS)
      7. 9.3.7  Input Source Dynamic Power Manage
      8. 9.3.8  Two-Level Adapter Current Limit (Peak Power Mode)
      9. 9.3.9  Processor Hot Indication
        1. 9.3.9.1 PROCHOT During Low Power Mode
        2. 9.3.9.2 PROCHOT Status
      10. 9.3.10 Device Protection
        1. 9.3.10.1 Watchdog Timer
        2. 9.3.10.2 Input Overvoltage Protection (ACOV)
        3. 9.3.10.3 Input Overcurrent Protection (ACOC)
        4. 9.3.10.4 System Overvoltage Protection (SYSOVP)
        5. 9.3.10.5 Battery Overvoltage Protection (BATOVP)
        6. 9.3.10.6 Battery Short
        7. 9.3.10.7 System Short Hiccup Mode
        8. 9.3.10.8 Thermal Shutdown (TSHUT)
    4. 9.4 Device Functional Modes
      1. 9.4.1 Forward Mode
        1. 9.4.1.1 System Voltage Regulation with Narrow VDC Architecture
        2. 9.4.1.2 Battery Charging
      2. 9.4.2 USB On-The-Go
      3. 9.4.3 Pass Through Mode (PTM)
    5. 9.5 Programming
      1. 9.5.1 SMBus Interface
        1. 9.5.1.1 SMBus Write-Word and Read-Word Protocols
        2. 9.5.1.2 Timing Diagrams
    6. 9.6 Register Map
      1. 9.6.1  Setting Charge and PROCHOT Options
        1. 9.6.1.1 ChargeOption0 Register (SMBus address = 12h) [reset = E70Eh]
        2. 9.6.1.2 ChargeOption1 Register (SMBus address = 30h) [reset = 0211h]
        3. 9.6.1.3 ChargeOption2 Register (SMBus address = 31h) [reset = 02B7h]
        4. 9.6.1.4 ChargeOption3 Register (SMBus address = 32h) [reset = 0030h]
        5. 9.6.1.5 ProchotOption0 Register (SMBus address = 33h) [reset = 4A65h]
        6. 9.6.1.6 ProchotOption1 Register (SMBus address = 34h) [reset = 81A0h]
        7. 9.6.1.7 ADCOption Register (SMBus address = 35h) [reset = 2000h]
      2. 9.6.2  Charge and PROCHOT Status
        1. 9.6.2.1 ChargerStatus Register (SMBus address = 20h) [reset = 0000h]
        2. 9.6.2.2 ProchotStatus Register (SMBus address = 21h) [reset = A800h]
      3. 9.6.3  ChargeCurrent Register (SMBus address = 14h) [reset = 0000h]
        1. 9.6.3.1 Battery Precharge Current Clamp
      4. 9.6.4  MaxChargeVoltage Register (SMBus address = 15h) [reset value based on CELL_BATPRESZ pin setting]
      5. 9.6.5  MinSystemVoltage Register (SMBus address = 3Eh) [reset value based on CELL_BATPRESZ pin setting]
        1. 9.6.5.1 System Voltage Regulation
      6. 9.6.6  Input Current and Input Voltage Registers for Dynamic Power Management
        1. 9.6.6.1 Input Current Registers
          1. 9.6.6.1.1 IIN_HOST Register With 10-mΩ Sense Resistor (SMBus address = 3Fh) [reset = 4100h]
          2. 9.6.6.1.2 IIN_DPM Register With 10-mΩ Sense Resistor (SMBus address = 022h) [reset = 4100h]
          3. 9.6.6.1.3 InputVoltage Register (SMBus address = 3Dh) [reset = VBUS-1.28V]
      7. 9.6.7  OTGVoltage Register (SMBus address = 3Bh) [reset = 0000h]
      8. 9.6.8  OTGCurrent Register (SMBus address = 3Ch) [reset = 0000h]
      9. 9.6.9  ADCVBUS/PSYS Register (SMBus address = 23h)
      10. 9.6.10 ADCIBAT Register (SMBus address = 24h)
      11. 9.6.11 ADCIINCMPIN Register (SMBus address = 25h)
      12. 9.6.12 ADCVSYSVBAT Register (SMBus address = 26h)
      13. 9.6.13 ID Registers
        1. 9.6.13.1 ManufactureID Register (SMBus address = FEh) [reset = 0040h]
        2. 9.6.13.2 Device ID (DeviceAddress) Register (SMBus address = FFh) [reset = 0h]
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
        1. 10.2.2.1 ACP-ACN Input Filter
        2. 10.2.2.2 Inductor Selection
        3. 10.2.2.3 Input Capacitor
        4. 10.2.2.4 Output Capacitor
        5. 10.2.2.5 Power MOSFETs Selection
      3. 10.2.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
      1. 12.2.1 Layout Example Reference Top View
      2. 12.2.2 Inner Layer Layout and Routing Example
  13. 13Device and Documentation Support
    1. 13.1 Device Support
      1. 13.1.1 Third-Party Products Disclaimer
    2. 13.2 Documentation Support
      1. 13.2.1 Related Documentation
    3. 13.3 Receiving Notification of Documentation Updates
    4. 13.4 Support Resources
    5. 13.5 Trademarks
    6. 13.6 Electrostatic Discharge Caution
    7. 13.7 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Timing Requirements

MINNOMMAXUNIT
SMBus TIMING CHARACTERISTICS
trSCLK/SDATA rise time300ns
tfSCLK/SDATA fall time300ns
tW(H)SCLK pulse width high0.650µs
tW(L)SCLK Pulse Width Low1.3µs
tSU(STA)Setup time for START condition0.6µs
tH(STA)START condition hold time after which first clock pulse is generated0.6µs
tSU(DAT)Data setup time100ns
tH(DAT)Data hold time300ns
tSU(STOP)Setup time for STOP condition0.6µs
t(BUF)Bus free time between START and STOP condition1.3µs
FS(CL) Clock Frequency 10 100 kHz
HOST COMMUNICATION FAILURE
ttimeoutSMBus bus release timeout(1)2535ms
tDeg_WDDeglitch for watchdog reset signal10ms
tWDIWatchdog timeout period, ChargeOption() bit [14:13] = 01(2)45.57s
Watchdog timeout period, ChargeOption() bit bit [14:13] = 10(2)7088105s
Watchdog timeout period, ChargeOption() bit bit [14:13] = 11(2)140175210s
Devices participating in a transfer will timeout when any clock low exceeds the 25ms minimum timeout period. Devices that have detected a timeout condition must reset the communication no later than the 35 ms maximum timeout period. Both a master and a slave must adhere to the maximum value specified as it incorporates the cumulative stretch limit for both a master (10 ms) and a slave (25 ms).
User can adjust threshold via SMBus ChargeOption() REG0x12().