SLUSAU1C May   2012  – May 2021 BQ34Z100

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics: Power-On Reset
    6. 6.6  Electrical Characteristics: LDO Regulator
    7. 6.7  Electrical Characteristics: Internal Temperature Sensor Characteristics
    8. 6.8  Electrical Characteristics: Low-Frequency Oscillator
    9. 6.9  Electrical Characteristics: High-Frequency Oscillator
    10. 6.10 Electrical Characteristics: Integrating ADC (Coulomb Counter) Characteristics
    11. 6.11 Electrical Characteristics: ADC (Temperature and Cell Measurement) Characteristics
    12. 6.12 Electrical Characteristics: Data Flash Memory Characteristics
    13. 6.13 Timing Requirements: HDQ Communication
    14. 6.14 Timing Requirements: I2C-Compatible Interface
    15. 6.15 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Feature Description
      1. 7.2.1  Data Commands
        1. 7.2.1.1 Standard Data Commands
        2. 7.2.1.2 Control(): 0x00/0x01
          1. 7.2.1.2.1  CONTROL_STATUS: 0x0000
          2. 7.2.1.2.2  DEVICE TYPE: 0x0001
          3. 7.2.1.2.3  FW_VERSION: 0x0002
          4. 7.2.1.2.4  HW_VERSION: 0x0003
          5. 7.2.1.2.5  RESET_DATA: 0x0005
          6. 7.2.1.2.6  PREV_MACWRITE: 0x0007
          7. 7.2.1.2.7  CHEM ID: 0x0008
          8. 7.2.1.2.8  BOARD_OFFSET: 0x0009
          9. 7.2.1.2.9  CC_OFFSET: 0x000A
          10. 7.2.1.2.10 CC_OFFSET_SAVE: 0x000B
          11. 7.2.1.2.11 DF_VERSION: 0x000C
          12. 7.2.1.2.12 SET_FULLSLEEP: 0x0010
          13. 7.2.1.2.13 STATIC_CHEM_DF_CHKSUM: 0x0017
          14. 7.2.1.2.14 SEALED: 0x0020
          15. 7.2.1.2.15 IT ENABLE: 0x0021
          16. 7.2.1.2.16 RESET: 0x0041
          17. 7.2.1.2.17 EXIT_CAL: 0x0080
          18. 7.2.1.2.18 ENTER_CAL: 0x0081
          19. 7.2.1.2.19 OFFSET_CAL: 0x0082
        3. 7.2.1.3 StateOfCharge(): 0x02/0x03
        4. 7.2.1.4 RemainingCapacity(): 0x04/0x05
        5. 7.2.1.5 FullChargeCapacity(): 0x06/07
        6. 7.2.1.6 Voltage(): 0x08/0x09
        7. 7.2.1.7 AverageCurrent(): 0x0A/0x0B
        8. 7.2.1.8 Temperature(): 0x0C/0x0D
        9. 7.2.1.9 Flags(): 0x0E/0x0F
      2. 7.2.2  Extended Data Commands
        1. 7.2.2.1  AtRate(): 0X10/0x11
        2. 7.2.2.2  AtRateTimeToEmpty(): 0x12/0x13
        3. 7.2.2.3  Current(): 0x10/0x11
        4. 7.2.2.4  NominalAvailableCapacity(): 0x14/0x15
        5. 7.2.2.5  FullAvailableCapacity(): 0x16/0x17
        6. 7.2.2.6  TimeToEmpty(): 0x18/0x19
        7. 7.2.2.7  TimeToFull(): 0x1A/0x1B
        8. 7.2.2.8  StandbyCurrent(): 0x1C/0x1D
        9. 7.2.2.9  StandbyTimeToEmpty(): 0x1E/0x1F
        10. 7.2.2.10 MaxLoadCurrent(): 0x20/0x21
        11. 7.2.2.11 MaxLoadTimeToEmpty(): 0x22/0x23
        12. 7.2.2.12 AvailableEnergy(): 0x24/0x25
        13. 7.2.2.13 AveragePower(): 0x26/0x27
        14. 7.2.2.14 TimeToEmptyAtConstantPower(): 0x28/0x29
        15. 7.2.2.15 InternalTemp(): 0x2A/0x2B
        16. 7.2.2.16 CycleCount(): 0x2C/0x2D
        17. 7.2.2.17 StateOfHealth(): 0x2E/0x2F
        18. 7.2.2.18 ChargeVoltage(): 0x30/0x31
        19. 7.2.2.19 ChargeCurrent(): 0x32/0x33
        20. 7.2.2.20 PassedCharge(): 0x34/0x35
        21. 7.2.2.21 DOD0(): 0x36/0x37
        22. 7.2.2.22 SelfDischargeCurrent(): 0x38/0x39
        23. 7.2.2.23 PackConfiguration(): 0x3A/0x3B
        24. 7.2.2.24 DesignCapacity(): 0x3C/0x3D
        25. 7.2.2.25 DataFlashClass(): 0x3E
        26. 7.2.2.26 DataFlashBlock(): 0x3F
        27. 7.2.2.27 AuthenticateData/BlockData(): 0x40…0x53
        28. 7.2.2.28 AuthenticateChecksum/BlockData(): 0x54
        29. 7.2.2.29 BlockData(): 0x55…0x5F
        30. 7.2.2.30 BlockDataChecksum(): 0x60
        31. 7.2.2.31 BlockDataControl(): 0x61
        32. 7.2.2.32 DeviceNameLength(): 0x62
        33. 7.2.2.33 DeviceName(): 0x63…0x6A
      3. 7.2.3  Data Flash Interface
        1. 7.2.3.1 Accessing Data Flash
        2. 7.2.3.2 Manufacturer Information Block
        3. 7.2.3.3 Access Modes
        4. 7.2.3.4 Sealing/Unsealing Data Flash Access
      4. 7.2.4  Data Flash Summary
      5. 7.2.5  Fuel Gauging
      6. 7.2.6  Impedance Track Variables
        1. 7.2.6.1  Load Mode
        2. 7.2.6.2  Load Select
        3. 7.2.6.3  Reserve Cap-mAh
        4. 7.2.6.4  Reserve Cap-mWh/cWh
        5. 7.2.6.5  Design Energy Scale
        6. 7.2.6.6  Dsg Current Threshold
        7. 7.2.6.7  Chg Current Threshold
        8. 7.2.6.8  Quit Current, Dsg Relax Time, Chg Relax Time, and Quit Relax Time
        9. 7.2.6.9  Qmax
        10. 7.2.6.10 Update Status
        11. 7.2.6.11 Avg I Last Run
        12. 7.2.6.12 Avg P Last Run
        13. 7.2.6.13 Delta Voltage
        14. 7.2.6.14 Ra Tables
        15. 7.2.6.15 Pack Configuration Register
          1. 7.2.6.15.1 Pack Configuration B Register
          2. 7.2.6.15.2 Pack Configuration C Register
      7. 7.2.7  Voltage Division and Calibration
        1. 7.2.7.1 1S Example
        2. 7.2.7.2 7S Example
        3. 7.2.7.3 Autocalibration
      8. 7.2.8  Temperature Measurement
      9. 7.2.9  Overtemperature Indication
        1. 7.2.9.1 Overtemperature: Charge
        2. 7.2.9.2 Overtemperature: Discharge
      10. 7.2.10 Charging and Charge Termination Indication
      11. 7.2.11 X10 Mode
      12. 7.2.12 Remaining State of Charge LED Indication
      13. 7.2.13 Alert Signal
      14. 7.2.14 Communications
        1. 7.2.14.1 Authentication
        2. 7.2.14.2 Key Programming
        3. 7.2.14.3 Executing an Authentication Query
        4. 7.2.14.4 HDQ Single-Pin Serial Interface
        5. 7.2.14.5 I2C Interface
      15. 7.2.15 Power Control
        1. 7.2.15.1 Reset Functions
        2. 7.2.15.2 Wake-Up Comparator
        3. 7.2.15.3 Flash Updates
    3. 7.3 Device Functional Modes
      1. 7.3.1 NORMAL Mode
      2. 7.3.2 SLEEP Mode
      3. 7.3.3 FULL SLEEP Mode
  8. Application and Implementation
    1. 8.1 Typical Applications
      1. 8.1.1 Design Requirements
      2. 8.1.2 Detailed Design Procedure
        1. 8.1.2.1 Step-by-Step Design Procedure
          1. 8.1.2.1.1 STEP 1: Review and Modify the Data Flash Configuration Data.
          2. 8.1.2.1.2 STEP 2: Review and Modify the Data Flash Configuration Registers.
          3. 8.1.2.1.3 STEP 3: Design and Configure the Voltage Divider.
          4. 8.1.2.1.4 STEP 4: Determine the Sense Resistor Value.
          5. 8.1.2.1.5 STEP 5: Review and Modify the Data Flash Gas Gauging Configuration, Data, and State.
          6. 8.1.2.1.6 STEP 6: Determine and Program the Chemical ID.
          7. 8.1.2.1.7 STEP 7: Calibrate.
          8. 8.1.2.1.8 STEP 8: Run an Optimization Cycle.
      3. 8.1.3 Battery Chemistry Configuration
        1. 8.1.3.1 Battery Chemistry Charge Termination
      4. 8.1.4 Replaceable Battery Systems
      5. 8.1.5 Digital Interface Options
      6. 8.1.6 Display Options
      7. 8.1.7 Application Curves
      8. 8.1.8 Special Applications
        1. 8.1.8.1 Operation Configuration B Register
        2. 8.1.8.2 Operation Configuration C Register
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
      1. 10.1.1 Introduction
      2. 10.1.2 Power Supply Decoupling Capacitor
      3. 10.1.3 Capacitors
      4. 10.1.4 Communication Line Protection Components
    2. 10.2 Layout Example
      1. 10.2.1 Ground System
      2. 10.2.2 Kelvin Connections
      3. 10.2.3 Board Offset Considerations
      4. 10.2.4 ESD Spark Gap
  11. 11Device and Documentation Support
    1. 11.1 Documentation Support
      1. 11.1.1 Related Documentation
    2. 11.2 Receiving Notification of Documentation Updates
    3. 11.3 Support Resources
    4. 11.4 Trademarks
    5. 11.5 Electrostatic Discharge Caution
    6. 11.6 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Voltage Division and Calibration

The device is shipped with a factory configuration for the default case of the 1-series Li-ion cell. This can be changed by setting the VOLTSEL bit in the Pack Configuration register and by setting the number of series cells in the data flash configuration section.

Multi-cell applications, with voltages up to 65535 mV, may be gauged by using the appropriate input scaling resistors such that the maximum battery voltage, under all conditions, appears at the BAT input as approximately 900 mV. The actual gain function is determined by a calibration process and the resulting voltage calibration factor is stored in the data flash location Voltage Divider.

For single-cell applications, an external divider network is not required. Inside the IC, behind the BAT pin is a nominal 5:1 voltage divider with 88 KΩ in the top leg and 22 KΩ in the bottom leg. This internal divider network is enabled by clearing the VOLTSEL bit in the Pack Configuration register. This ratio is optimum for directly measuring a single Li-ion cell where charge voltage is limited to 4.5 V.

For higher voltage applications, an external resistor divider network should be implemented as per the reference designs in this document. The quality of the divider resistors is very important to avoid gauging errors over time and temperature. It is recommended to use 0.1% resistors with 25-ppm temperature coefficient. Alternately, a matched network could be used that tracks its dividing ratio with temperature and age due to the similar geometry of each element. Calculation of the series resistor can be made per the equation below.

Note:

Exceeding Vin max mV results in a measurement with degraded linearity.

The bottom leg of the divider resistor should be in the range of 15 KΩ to 25 K, using 16.5 KΩ:

Rseries = 16500 Ω (Vin max mV – 900 mV)/900 mV

For all applications, the Voltage Divider value in data flash will be used by the firmware to calibrate the total divider ratio. The nominal value for this parameter is the maximum expected value for the stack voltage. The calibration routine adjusts the value to force the reported voltage to equal the actual applied voltage.