SLUSCM6E June 2016 – April 2019 BQ35100
PRODUCTION DATA.
For the primary battery current, the integrating delta-sigma ADC in the device measures the discharge current of the battery by measuring the voltage drop across a small-value sense resistor between the SRP and SRN pins, and is available through the Current() command.