SLUSCM6E June 2016 – April 2019 BQ35100
PRODUCTION DATA.
MIN | NOM | MAX | UNIT | |||
---|---|---|---|---|---|---|
VREGIN | Supply Voltage | No operating restrictions | 2.7 | 4.5 | V | |
No FLASH writes | 2.45 | 2.7 | V | |||
CREGIN | External input capacitor for internal LDO between REGIN and VSS | Nominal capacitor values specified. Recommend a 10% ceramic X5R type capacitor located close to the device. | 0.1 | µF | ||
CLDO25 | External output capacitor for internal LDO between VREG25 | 0.47 | 1 | µF | ||
ICC_GELOW(1) | Gas gauge in Disabled mode | GE = Low | 0.05 | µA | ||
ICC_ACC_AVE(1) | Gas gauge in ACCUMULATOR mode average current | Update every 30 minutes otherwise GE = Low | 0.3 | µA | ||
ICC_SOH_AVE(1) | State-of-health average current | Update every 8 hours otherwise GE = Low | 0.06 | µA | ||
ICC_EOS_AVE(1) | End-of-service average current | Update every 8 hours 3- s Load Pulse otherwise GE = Low | 0.35 | µA | ||
VA1 | Input voltage range (VIN, TS) | VSS – 0.05 | 1 | V | ||
VA2 | Input voltage range (BAT) | VSS – 0.125 | 5.0 | V | ||
VA3 | Input voltage range (SRP, SRN) | VSS – 0.125 | 0.125 | V | ||
ILKG | Input leakage current (I/O pins) | 0.3 | µA | |||
tPUCD | Power-up communication | 250 | ms |