SLUSBV4B June 2018 – September 2020 BQ40Z80
PRODUCTION DATA
Table 9-1 shows the default settings for the main parameters. Use the BQSTUDIO tool to update the settings to meet the specific application or battery pack configuration requirements.
The device should be calibrated before any gauging test. Follow the BQSTUDIO Calibration page to calibrate the device, and use the BQSTUDIO Chemistry page to update the match chemistry profile to the device. Design Parameters shows all of the settings that are configurable in BQSTUDIO and in the BQ40Z80 firmware.
DESIGN PARAMETER | EXAMPLE |
---|---|
Cell Configuration | 6s (6-series)(1) |
Design Capacity | 6000 mAh |
Device Chemistry | 1210 (LiCoO2/graphitized carbon) |
Cell Overvoltage at Standard Temperature | 4300 mV |
Cell Undervoltage | 2500 mV |
Shutdown Voltage | 2300 mV |
Overcurrent in CHARGE Mode | 6000 mA |
Overcurrent in DISCHARGE Mode | –6000 mA |
Short Circuit in CHARGE Mode | 0.1 V/Rsense across SRP, SRN |
Short Circuit in DISCHARGE Mode | 0.1 V/Rsense across SRP, SRN |
Safety Overvoltage | 4500 mV |
Cell Balancing | Disabled |
Internal and External Temperature Sensor | External Temperature Sensor is used. |
Undertemperature Charging | 0°C |
Undertemperature Discharging | 0°C |
BROADCAST Mode | Disabled |