4 Revision History
Changes from E Revision (March 2015) to F Revision
-
Changed all Qi v1.1 and WPC v1.1 To: Qi v1.2 and WPC v1.2 throughout the documentGo
-
Added the Adaptive Communication Limit sectionGo
-
Deleted R1 = 29.402 kΩ R3 = 14.302 kΩ and added a link to SLUS629 in the Internal Temperature Sense (TS Function of the TS/CTRL Pin) section Go
Changes from D Revision (January 2014) to E Revision
-
Added ESD Ratings table, Feature Description section, Device Functional Modes, Application and Implementation section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable Information sectionGo
-
Added the bq51052B 4.40-V optionGo
-
Updated pinout imagesGo
-
Added thermal pad description in Pin Functions tableGo
-
Added AD voltage to Recommended Operating ConditionsGo
-
Changed RECT overvoltage specification name from VRECT to VOVPGo
-
Changed to ILIM_SHORT, OK from ILIM_SC for clarityGo
-
Added VOREG for bq51052BGo
-
Added minimum current for KILIMGo
-
Changed KILIM TYP value from 300 to 314 (min / max also changed)Go
-
Added IBULK spec for charging minimum and maximumGo
-
Added VRECH for bq51052BGo
-
Added new spec ITerminationGo
-
Changed to VTSB from VTS for clarityGo
-
Changed from ITS-Bias for clarityGo
-
Deleted V0C-F as redundantGo
-
Changed typical JEITA regulation on bq51050B from 4.10 V to 4.06 VGo
-
Changed to clarify CTRL pin high and low levelsGo
-
Changed Thermal shutdown name to TJ-SD for clarityGo
-
Added section to describe Adapter Enable functionGo
-
Changed Synchronous rectifer switchover name to IBAT-SR for clarityGo
-
Added synchronous mode entry for bq51052BGo
-
Deleted note regarding internal junction monitor reducing current - it is not applicable.Go
-
Added section on modified JEITA profile for bq51052BGo
-
Changed TS/CTRL function to correct Termination Packet valueGo
-
Added Taper mode completion for Termination PacketGo
-
Changed Beta value from 4500 to 3380 to match NTC datasheetGo
-
Changed received power maximum error from 250 mW to 375 mW to comply with latest WPC v1.2 specificationGo
Changes from C Revision (February 2013) to D Revision
-
Changed the ABSOLUTE MAXIMUM RATINGS - moved AC1 and AC2 onto a single row with a Min value of –0.8 Go
-
Added section: Details of a Qi Wireless Power System and bq5105xB Power Transfer Flow DiagramsGo
-
Changed text in the Battery Charge Profile sectionGo
-
Changed Battery failure Conditions in Table 1Go
-
Changed Equation 3 and Equation 4Go
-
Changed R2 = 7.81 kΩ To: R1 = 29.402 kΩGo
-
Changed R3 = 13.98 kΩ To: R3 = 14.302 kΩ in the Internal Temperature Sense (TS Function of the TS/CTRL Pin) sectionGo
-
Changed THOT = 0°C To: THOT = 60°CGo
-
Changed Equation 6Go
Changes from B Revision (September 2012) to C Revision
-
First release of the full data sheetGo
Changes from A Revision (August 2012) to B Revision
-
Changed last features bullet from: 1.9 x 3.0mm WCSP and 4.5 x 3.5mm QFN Package Options to: Available in small WCSP and QFN packagesGo
-
Changed Figure 1 and changed caption from: Wireless Power Consortium (WPC or Qi) Inductive Power Charging System, to: Typical System blocks shows bq5105xB used as a Wireless Power Li-Ion/Li-Pol Battery ChargerGo
-
Added note: Visit ti.com/wirelesspower for product details and design resourcesGo
Changes from * Revision (August 2012) to A Revision
-
Changed Regulated BAT(output) voltageGo
-
Changed Recharge threshold for bq51052BGo
-
Deleted ITS-Bias-MaxGo
-
Changed VCOLD to VOC and valuesGo
-
Changed V45C valuesGo
-
Changed V60C valuesGo
-
Changed Figure 25Go
-
Changed Figure 25Go