The BQ77307 device
supports a normal operating mode as well as a full shutdown mode, with the device able to
transition from NORMAL mode to SHUTDOWN mode autonomously, based on settings.
- NORMAL mode: In this mode, the device evaluates
system current, cell voltages, internal and thermistor temperature, and various diagnostic
checks, operates protections as configured, and provides interrupt and status updates.
Battery protections are enabled, and the FET drivers are typically enabled (in the absence
of any protection fault).
- SHUTDOWN mode: The device is completely disabled
(including the internal 1.8 V and REGOUT LDOs), the CHG and DSG FETs are both
disabled, and all battery protections are disabled. This is the lowest power
state of the device, which may be used for shipment or long-term storage. All
register settings that were not written into OTP by TI are lost when in SHUTDOWN
mode.
The device also includes a CONFIG_UPDATE mode,
which is used for parameter updates. Transitioning between operational modes is shown in
BQ77307 Power Modes.