SLUSEC2A December 2021 – November 2023 BQ79631-Q1
PRODUCTION DATA
Address | 0x030D | |||||||
RW | Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
Name | RSVD | CS_DR[1:0] | LPF_CSAUX_EN | LPF_VS _EN | CS_MAIN_GO | MAIN_MODE[1:0] | ||
Reset | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
RSVD = | Reserved | |||||||
CS_DR[1:0] = | Configures the desired single
measurement time of the CS ADC. 00 = 768 μs 01 = 1.536 ms 10 = 3.072 ms 11 = 12.288 ms |
|||||||
LPF_CSAUX_EN = | Enables digital low-pass filter post-ADC conversion. LPF applies to CSAUX measurements only. The cut-off frequency is configured by ADC_CONFIG1[LPF_CSAUX[2:0]. | |||||||
LPF_VS_EN = | Enables digital low-pass filter post-ADC conversion. LPF applies to VS measurements only. The cut-off frequency is configured by ADC_CONFIG1[LPF_VS[2:0]. NOTE: Need an OTP bit as a global enable or disable to the digital LPF function for VS and SRP/N. | |||||||
CS_MAIN_GO = | Starts main ADC conversion. When this bit is written to 1, all
Main ADC inputs are sampled. Once the Main ADC is started, any
change to the Main ADC control setting has no effect until this bit
is written to 1 again. This bit is cleared to 0 in read. 0 = Ready. Writing 0 has no effect 1 = Start Main ADC This control also applies to the CS ADC.In sleep mode, CS ADC need to be disabled, otherwise, it consumes extra current ICS_ADC. | |||||||
MAIN_MODE[1:0] = | Sets the Main ADC run mode. In continuous run, if user would
like to stop ADC, user must read all the ADC conversion results,
then stop it. ADC results are not valid before ADC is re-enabled
next time. 00 = Main ADC not running 01 = Single run. Run the main ADC round robin 8 times and then stop 10 = Continuous run. Continuous running the Main ADC round robin until host sends command to stop 11 = Reserved |