SCHS240D November   1998  – October 2024 CD54AC164 , CD54ACT164 , CD74AC164 , CD74ACT164

PRODUCTION DATA  

  1.   1
  2. Features
  3. Description
  4. Pin Configuration and Functions
  5. Specifications
    1. 4.1 Absolute Maximum Ratings
    2. 4.2 ESD Ratings
    3. 4.3 Recommended Operating Conditions
    4. 4.4 Thermal Information
    5. 4.5 DC Electrical Specifications
    6. 4.6 Prerequisite for Switching Function
    7. 4.7 Switching Specifications
  6. Parameter Measurement Information
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Standard CMOS Inputs
      2. 6.3.2 TTL-Compatible CMOS Inputs
    4. 6.4 Device Functional Modes
  8. Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Typical Application
      1. 7.2.1 Design Requirements
        1. 7.2.1.1 Power Considerations
        2. 7.2.1.2 Input Considerations
        3. 7.2.1.3 Output Considerations
        4. 7.2.1.4 Application Curve
    3. 7.3 Power Supply Recommendations
    4. 7.4 Layout
      1. 7.4.1 Layout Guidelines
      2. 7.4.2 Layout Example
  9. Device and Documentation Support
    1. 8.1 Documentation Support
      1. 8.1.1 Related Documentation
    2. 8.2 Receiving Notification of Documentation Updates
    3. 8.3 Support Resources
    4. 8.4 Trademarks
    5. 8.5 Electrostatic Discharge Caution
    6. 8.6 Glossary
  10. Device and Documentation Support
    1. 9.1 Documentation Support (Analog)
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • J|14
Thermal pad, mechanical data (Package|Pins)

DC Electrical Specifications

PARAMETER TEST CONDITIONS VCC (V) 25°C -40°C TO 85 °C -55°C TO 125°C UNITS
VI (V) IO (mA) MIN MAX MIN MAX MIN MAX
AC TYPES
VIH High Level Input Voltage - - 1.5 1.2 - 1.2 - 1.2 - V
3 2.1 - 2.1 - 2.1 - V
5.5 3.85 - 3.85 - 3.85 - V
VIL Low Level Input Voltage - - 1.5 - 0.3 - 0.3 - 0.3 V
3 - 0.9 - 0.9 - 0.9 V
5.5 - 1.65 - 1.65 - 1.65 V
VOH High Level Output Voltage VIH or VIL -0.05 1.5 1.4 - 1.4 - 1.4 - V
-0.05 3 2.9 - 2.9 - 2.9 - V
-0.05 4.5 4.4 - 4.4 - 4.4 - V
-4 3 2.58 - 2.48 - 2.4 - V
-24 4.5 3.94 - 3.8 - 3.7 - V
-75 (1)(2) 5.5 - - 3.85 - - - V
-50 (1)(2) 5.5 - - - - 3.85 - V
VOL Low Level Output Voltage VIH or VIL 0.05 1.5 - 0.1 - 0.1 - 0.1 V
0.05 3 - 0.1 - 0.1 - 0.1 V
0.05 4.5 - 0.1 - 0.1 - 0.1 V
12 3 - 0.36 - 0.44 - 0.5 V
24 4.5 - 0.36 - 0.44 - 0.5 V
75 (1)(2) 5.5 - - - 1.65 - - V
50(1)(2) 5.5 - - - - - 1.65 V
II Input Leakage Current VCC or GND - 5.5 - ±0.1 - ±1 - ±1 μA
ICC Quiescent Supply Current MSI VCC or GND 0 5.5 - 8 - 80 - 160 μA
ACT TYPES
VIH High Level Input Voltage - - 4.5 to 5.5 2 - 2 - 2 - V
VIL Low Level Input Voltage - - 4.5 to 5.5 - 0.8 - 0.8 - 0.8 V
VOH High Level Output Voltage VIH or VIL -0.05 4.5 4.4 - 4.4 - 4.4 - V
-24 4.5 3.94 - 3.8 - 3.7 - V
-75(1)(2) 5.5 - - 3.85 - - - V
-50 (1)(2) 5.5 - - - - 3.85 - V
VOL Low Level Output Voltage VIH or VIL 0.05 4.5 - 0.1 - 0.1 - 0.1 V
24 4.5 - 0.36 - 0.44 - 0.5 V
75 (1)(2) 5.5 - - - 1.65 - - V
50 (1)(2) 5.5 - - - - - 1.65 V
II Input Leakage Current VCC or GND - 5.5 - ±0.1 - ±1 - ±1 μA
ICC Quiescent Supply Current MSI VCC or GND 0 5.5 - 8 - 80 - 160 μA
ΔICC Additional Supply Current per Input Pin TTL Inputs High 1 Unit Load VCC -2.1 - 4.5 to 5.5 - 2.4 - 2.8 - 3 mA
Test one output at a time for a 1-second maximum duration. Measurement is made by forcing current and measuring voltage to minimize power dissipation.
Test verifies a minimum 50Ω transmission-line-drive capability at 85°C, 75Ω at 125°C.
Table 4-1 ACT Input Load Table
INPUT UNIT LOAD
A, B 0.5
CLR 0.74
CLK 0.71

Unit load is ΔICC limit specified in DC Electrical Specifications Table, e.g., 2.4mA max at 25°C.