SCHS188E November   1998  – October 2022 CD54HC534 , CD54HC564 , CD54HCT534 , CD54HCT564 , CD74HC534 , CD74HC564 , CD74HCT534 , CD74HCT564

PRODUCTION DATA  

  1. Features
  2. Description
  3. Revision History
  4. Pin Configuration and Functions
  5. Specifications
    1. 5.1 Absolute Maximum Ratings (1)
    2. 5.2 Recommended Operating Conditions
    3. 5.3 Thermal Information
    4. 5.4 Electrical Characteristics
    5. 5.5 Prerequisite for Switching Characteristics
    6. 5.6 Switching Characteristics
  6. Parameter Measurement Information
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Device Functional Modes
  8. Power Supply Recommendations
  9. Layout
    1. 9.1 Layout Guidelines
  10. 10Device and Documentation Support
    1. 10.1 Receiving Notification of Documentation Updates
    2. 10.2 Support Resources
    3. 10.3 Trademarks
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 Glossary
  11. 11Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • J|20
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

PARAMETER TEST CONDITIONS(2) VCC (V) 25℃ –40℃ to 85℃ –55℃ to 125℃ UNIT
MIN TYP MAX MIN MAX MIN MAX
HC TYPES
VIH High level input voltage 2 1.5 1.5 1.5 V
4.5 3.15 3.15 3.15
6 4.2 4.2 4.2
VIL Low level input voltage 2 0.5 0.5 0.5 V
4.5 1.35 1.35 1.35
6 1.8 1.8 1.8
VOH

High level output voltage

IOH = –20 µA 2 1.9 1.9 1.9 V
IOH = –20 µA 4.5 4.4 4.4 4.4
IOH = –20 µA 6 5.9 5.9 5.9

High level output voltage

IOH = –6 mA 4.5 3.98 3.84 3.7
IOH = –7.8 mA 6 5.48 5.34 5.2
VOL

Low level output voltage

IOL = 20 µA 2 0.1 0.1 0.1 V
IOL = 20 µA 4.5 0.1 0.1 0.1
IOL = 20 µA 6 0.1 0.1 0.1

Low level output voltage

IOL = 6 mA 4.5 0.26 0.33 0.4
IOL = 7.8 mA 6 0.26 0.33 0.4
II Input leakage current VI = VCC or GND 6 ±0.1 ±1 ±1 µA
ICC Supply current VI = VCC or GND 6 8 80 160 µA
IOZ Three-state leakage current VO = VCC or GND 6 ±0.5 ±5.0 ±10 µA
HCT TYPES
VIH High level input voltage 4.5 to 5.5 2 2 2 V
VIL Low level input voltage 4.5 to 5.5 0.8 0.8 0.8 V
VOH

High level output voltage

VOH = –20 µA 4.5 4.4 4.4 4.4 V

High level output voltage

VOH = –6 mA 4.5 3.98 3.84 3.7
VOL

Low level output voltage

VOL = 20 µA 4.5 0.1 0.1 0.1 V

Low level output voltage

VOL = 6 mA 4.5 0.26 0.33 0.4
II Input leakage current VI = VCC and GND 5.5 ±0.1 ±1 ±1 µA
ICC Supply current VI = VCC and GND 5.5 8 80 160 µA
IOZ Three-state leakage current VO = VCC or GND 5.5 ±0.5 ±5.0 ±10 µA
ΔICC(1) Additional supply current per input pin D0 - D7 inputs held at VCC –2.1 4.5 to 5.5 100 54 67.5 73.5 µA
CP input held at VCC –2.1 4.5 to 5.5 100 108 135 147
OE input held at VCC –2.1 4.5 to 5.5 100 198 247.5 269.5
For dual-supply systems theoretical worst case (VI = 2.4 V, VCC = 5.5 V) specification is 1.8 mA.
VI = VIH or VIL.