SCHS382A January   2010  – August 2022 CD74HC366-Q1

PRODUCTION DATA  

  1. Features
  2. Description
  3. Revision History
  4. Pin Configuration and Functions
  5. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
  6. Parameter Measurement Information
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Device Functional Modes
  8. Power Supply Recommendations
  9. Layout
    1. 9.1 Layout Guidelines
  10. 10Device and Documentation Support
    1. 10.1 Receiving Notification of Documentation Updates
    2. 10.2 Support Resources
    3. 10.3 Trademarks
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 Glossary
  11. 11Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Switching Characteristics

CL = 50pF. Input tr, tf = 6ns
PARAMETER VCC (V) 25°C -40°C TO 125°C UNITS
TYP MAX MAX
HC Types
tPLH,
tPHL
Propagation delay, data to outputs HC365 2 110 165 ns
4.5 22 33
6 19 28
HC366 2 150 225
4.5 31 45
6 26 38
tTLH,
tTHL
Output transition time 2 60 90 ns
4.5 12 18
6 10 15
CI Input capacitance 10 10 pF
CO Three-state output capacitance 20 20 pF
CPD Power dissipation capacitance(1)(2) 5 40 pF
HCT Types
tPLH, tPHL Propagation delay, data to outputs HCT365 4.5 25 38 ns
HCT366 4.5 27 41
tPLH, tPHL Propagation delay, output enable and disable to outputs 4.5 35 53 ns
tTLH, tTHL Output transition time 4.5 12 18 ns
CI Input capacitance 10 10 pF
CO Three-state output capacitance 20 20 pF
CPD Power dissipation capacitance(1)(2) 5 42 pF
CPD is used to determine the dynamic power consumption, per inverter.
PD = VCC2 × fi (CPD + CL), where fi = input frequency, CL = output load capacitance, VCC = supply voltage.