SCLS552B December   2003  – April 2024 CD74HC4051-Q1

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Recommended Operating Conditions
    3. 5.3 Recommended Operating Area as a Function of Supply Voltages
    4. 5.4 Electrical Characteristics
    5. 5.5 Switching Characteristics
    6. 5.6 Operating Characteristics
    7. 5.7 Analog Channel Characteristics
    8. 5.8 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Functional Block Diagram
    2. 7.2 Device Functional Modes
  9. Device and Documentation Support
    1. 8.1 Receiving Notification of Documentation Updates
    2. 8.2 Support Resources
    3. 8.3 Trademarks
    4. 8.4 Electrostatic Discharge Caution
    5. 8.5 Glossary
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • PW|16
  • D|16
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS VEE VCC TA = 25 °C TA = −40 °C TO 125°C UNIT
MIN TYP MAX MIN MAX
ronIO = 1 mA, VI = VIH or VIL, See Figure 5-3VIS = VCC or VEE0V4.5V70160240Ω
0V6V60140210
−4.5V4.5V40120180
VIS = VCC to VEE0V4.5V90180270
0V6V80160240
−4.5V4.5V45130195
ΔronBetween any two channels0V4.5V10Ω
0V6V8.5
−4.5V4.5V5
IIZ

For switch OFF:

When VIS = VCC, VOS = VEE; When VIS = VEE, VOS = VCC

For switch ON:

All applicable combinations of VIS and VOS voltage levels, VI = VIH or VIL

0V6V±0.2±2μA
−5V5V±0.4±4
IILVI = VCC or GND0V6V±0.1±1μA
ICCIO = 0, VI = VCC or GNDWhen VIS = VEE, VOS = VCC0V6V12160μA
When VIS = VCC, VOS = VEE−5V5V32320