SCHS122N November   1997  – April 2024 CD54HC4051 , CD54HC4052 , CD54HC4053 , CD54HCT4051 , CD74HC4051 , CD74HC4052 , CD74HC4053 , CD74HCT4051 , CD74HCT4052 , CD74HCT4053

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Thermal Information
    4. 5.4  Recommended Operating Conditions
    5. 5.5  Electrical Characteristics: HC Devices
    6. 5.6  Electrical Characteristics: HCT Devices
    7. 5.7  Switching Characteristics, VCC = 5V
    8. 5.8  Switching Characteristics, CL = 50pF
    9. 5.9  Analog Channel Specifications
    10. 5.10 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagrams
    3. 7.3 Feature Description
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • N|16
  • D|16
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Switching Characteristics, VCC = 5V

VCC = 5V, TA = 25°C, input tr,tf = 6 ns
Parameter Test Conditions CL (pF) MIN NOM MAX UNIT
tPHL, tPLH Supply voltage range (TA = full package temperature range)
Switch IN to OUT


CDx4HC4051 15 4 ns
CDx4HCT4051 4
CDx4HC4052 4
CDx4HCT4052 4
CDx4HC4053 4
CDx4HCT4053 4
tPHZ, tPLZ Switch turn-off (S or E)

 
CDx4HC4051 15 27
CDx4HCT4051 35
CDx4HC4052 33
CDx4HCT4052 33
CDx4HC4053 30
CDx4HCT4053 35
tPZH, tPZL Switch turn-on (S or E)

 
CDx4HC4051 15 19
CDx4HCT4051 23
CDx4HC4052 27
CDx4HCT4052 29
CDx4HC4053 18
CDx4HCT4053 28
CPD Power dissipation capacitance(1) CDx4HC4051 50 pF
CDx4HCT4051 52
CDx4HC4052 74
CDx4HCT4052 76
CDx4HC4053 38
CDx4HCT4053 42
CPD is used to determine the dynamic power consumption, per package. PD = CPD vCC2 fi + Σ (CL + CS)  VCC2 fO, fO= output frequency, fI = input frequency, CL = output load capacitance, CS = switch capacitance, VCC = supply voltage