6 Revision History
Changes from Revision A (October 2023) to Revision B (March 2024)
- Updated the numbering format for tables, figures, and
cross-references throughout the document.Go
Changes from Revision * (September 2012) to Revision A (January 2015)
- Added part number to title Go
- Increased the TC = 25° continuous drain current to 142AGo
- Increased the TC = 125° continuous drain current to 100A Go
- Increased the pulsed drain current to 358A Go
- Increased the max power dissipation to 188WGo
- Increased the max operating junction and storage temperature to 175°CGo
- Updated the pulsed current conditions Go
- Updated
Figure 4-1
from a normalized RθJA to an RθJC curveGo
- Updated
Figure 4-6
to extend to 175°C Go
- Updated
Figure 4-8
to extend to 175°C Go
- Updated the SOA in
Figure 4-10
Go
- Updated
Figure 4-12
to extend to 175°C Go