4 Revision History
Changes from A Revision (January 2014) to B Revision
- Increased pulsed drain current to 337A Go
- Added line for max power dissipation with case temperature held to 25°C Go
- Changed Figure 1 from a normalized RθJA curve to a normalized RθJC curveGo
- Updated the safe operating area in Figure 10Go
Changes from * Revision (September 2013) to A Revision
- Added more information to descriptionGo
- Added small reel order numberGo
- Removed TC = 25°C condition from continuous drain current (package limited) in Absolute Maximum Ratings tableGo
- Updated the pulsed drain current conditions Go