SLPS598E
May 2017 – June 2024
CSD88584Q5DC
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Specifications
4.1
Absolute Maximum Ratings
4.2
Recommended Operating Conditions
4.3
Power Block Performance
4.4
Thermal Information
4.5
Electrical Characteristics
4.6
Typical Power Block Device Characteristics
4.7
Typical Power Block MOSFET Characteristics
5
Application and Implementation
5.1
Application Information
5.2
Brushless DC Motor With Trapezoidal Control
5.3
Power Loss Curves
5.4
Safe Operating Area (SOA) Curve
5.5
Normalized Power Loss Curves
5.6
Design Example – Regulate Current to Maintain Safe Operation
5.7
Design Example – Regulate Board and Case Temperature to Maintain Safe Operation
5.7.1
Operating Conditions
5.7.2
Calculating Power Loss
5.7.3
Calculating SOA Adjustments
6
Layout
6.1
Layout Guidelines
6.1.1
Electrical Performance
6.1.2
Thermal Considerations
6.2
Layout Example
7
Device and Documentation Support
7.1
Receiving Notification of Documentation Updates
7.2
Support Resources
7.3
Trademarks
7.4
Electrostatic Discharge Caution
7.5
Glossary
8
Revision History
9
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
DMM|22
MPSS081A
Thermal pad, mechanical data (Package|Pins)
Orderable Information
slps598e_oa
slps598e_pm
5.7.2
Calculating Power Loss
Power loss at 40A ≈ 4.7W (
Figure 4-1
)
Normalized power loss for switching frequency ≈ 1.24 (
Figure 4-4
)
Normalized power loss for input voltage ≈ 1.09 (
Figure 4-5
)
Normalized power loss for duty cycle ≈ 1.06 (
Figure 4-6
)
Final calculated power loss = 4.7W × 1.24 × 1.09 × 1.06 ≈ 6.7W