DLPS124D
november 2018 – july 2023
DLP3310
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Revision History
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
Storage Conditions
6.3
ESD Ratings
6.4
Recommended Operating Conditions
6.5
Thermal Information
6.6
Electrical Characteristics
6.7
Timing Requirements
6.8
Switching Characteristics
6.9
System Mounting Interface Loads
6.10
Micromirror Array Physical Characteristics
6.11
Micromirror Array Optical Characteristics
6.12
Window Characteristics
6.13
Chipset Component Usage Specification
6.14
Software Requirements
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
Power Interface
7.3.2
Low-Speed Interface
7.3.3
High-Speed Interface
7.3.4
Timing
7.4
Device Functional Modes
7.5
Optical Interface and System Image Quality Considerations
7.5.1
Numerical Aperture and Stray Light Control
7.5.2
Pupil Match
7.5.3
Illumination Overfill
7.6
Micromirror Array Temperature Calculation
7.7
Micromirror Power Density Calculation
7.8
Micromirror Landed-On/Landed-Off Duty Cycle
7.8.1
Definition of Micromirror Landed-On/Landed-Off Duty Cycle
7.8.2
Landed Duty Cycle and Useful Life of the DMD
7.8.3
Landed Duty Cycle and Operational DMD Temperature
7.8.4
Estimating the Long-Term Average Landed Duty Cycle of a Product or Application
8
Application and Implementation
8.1
Application Information
8.2
Typical Application
8.2.1
Design Requirements
8.2.2
Detailed Design Procedure
8.2.3
Application Curve
9
Power Supply Recommendations
9.1
Power Supply Power-Up Procedure
9.2
Power Supply Power-Down Procedure
9.3
Power Supply Sequencing Requirements
10
Layout
10.1
Layout Guidelines
10.2
Layout Example
11
Device and Documentation Support
11.1
Third-Party Products Disclaimer
11.2
Device Support
11.2.1
Device Nomenclature
11.2.2
Device Markings
11.3
Documentation Support
11.4
Receiving Notification of Documentation Updates
11.5
Support Resources
11.6
Trademarks
11.7
Electrostatic Discharge Caution
11.8
Glossary
12
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
FQM|92
MCSS002A
Thermal pad, mechanical data (Package|Pins)
Orderable Information
dlps124d_oa
dlps124d_pm
6.9
System Mounting Interface Loads
PARAMETER
MIN
NOM
MAX
UNIT
Maximum system mounting interface load to be applied to the:
Thermal Interface Area
(1)
60
N
Clamping and Electrical Interface Area
(1)
110
N
(1)
Uniformly distributed within area shown in
Figure 6-14
.
Figure 6-14
System Interface Loads