During power-up, VDD must always start
and settle before VOFFSET plus
tDELAY1 specified in the Power
Supply Sequence Requirements,
VBIAS, and VRESET voltages
are applied to the DMD.
During power-up, it is a strict requirement that
the voltage difference between VBIAS
and VOFFSET must be within the
specified limit shown in the Recommended
Operating Conditions.
During power-up, there is no requirement for the relative timing of VRESET with respect to VBIAS.
Power supply slew rates during power-up are
flexible, provided that the transient voltage
levels follow the requirements specified in the
Absolute Maximum Ratings, Recommended
Operating Conditions, and the DMD Power
Supply Requirements.
During power-up, LVCMOS input pins must not be
driven high until after VDD has settled
at operating voltage listed in the Recommended
Operating Conditions.