DLPS227A october   2021  – june 2023 DLPA300

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics Control Logic
    6. 6.6  5-V Linear Regulator
    7. 6.7  Bias Voltage Boost Converter
    8. 6.8  Reset Voltage Buck-Boost Converter
    9. 6.9  VOFFSET Regulator
    10. 6.10 Switching Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 5-V Linear Regulator
      2. 7.3.2 Bias Voltage Boost Converter
      3. 7.3.3 Reset Voltage Buck-Boost Converter
      4. 7.3.4 VOFFSET Regulator
      5. 7.3.5 Serial Communications Port (SCP)
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Component Selection Guidelines
      3. 8.2.3 Application Curves
  10. Power Supply Recommendations
    1. 9.1 Power Supply Rail Guidelines
  11. 10Layout
    1. 10.1 Layout Guidelines
      1. 10.1.1 Grounding Guidelines
    2. 10.2 Thermal Considerations
  12. 11Device and Documentation Support
    1. 11.1 Third-Party Products Disclaimer
    2. 11.2 Device Support
      1. 11.2.1 Device Nomenclature
    3. 11.3 Documentation Support
      1. 11.3.1 Related Documentation
    4. 11.4 Receiving Notification of Documentation Updates
    5. 11.5 Support Resources
    6. 11.6 Trademarks
    7. 11.7 Electrostatic Discharge Caution
    8. 11.8 Glossary
  13. 12Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • PFP|80
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Recommended Operating Conditions

at TA = 25°C, P12V = 10.8 V to 13.2 V (unless otherwise noted)(2)
POWERMINNOMMAXUNIT
IP12V1P12V supply current(1)Global shadow at 50 kHz, OUT load = 39 Ω and 410 pF, V5REG = 30 mA, VBIAS = 21 V at 5 mA, VOFFSET = 10V at 30 mA200mA
IP12V2Outputs disabled and no external loads, VBIAS = 21 V, VOFFSET = 4.5 V22mA
TJTSDRThermal shutdown temperatureWith device temperature rising145160175°C
Hysteresis51015°C
Delta between thermal shutdown and thermal warning51015°C
TJTWRThermal warning temperatureWith device temperature rising125140155°C
Hysteresis51015°C
During power up the inrush power supply current can be as high as 1 A for a momentary period of time.
The functional performance of the device specified in this data sheet is achieved when operating the device within the limits defined by the Recommended Operating Conditions. No level of performance is implied when operating the device above or below the Recommended Operating Conditions limits.