SLLSEC6E September 2012 – June 2019 DP83848-EP
PRODUCTION DATA.
The 100 Base TX Link monitor ensures that a valid and stable link is established before enabling both the Transmit and Receive PCS layer.
Signal detect must be valid for 395 µs to allow the link monitor to enter the 'Link Up' state, and enable the transmit and receive functions.