SNLS341C March 2011 – March 2015 DP83848Q-Q1
PRODUCTION DATA.
The device is 10/100 Mbps Ethernet transceiver with an extended temperature range of –40°C to 105°C. The ability to perform over extreme temperatures makes this device ideal for demanding environments like Automotive, Transportation and Industrial Applications.
The device is AEC-Q100 Grade 2 certified. Its 3.3-V operating voltage and less than 270-mW typical power consumption makes this device suitable for low power applications.
The device has Auto MDIX capability to select MDI or MDIX automatically. The device supports Auto-Negotiation for selecting the highest performance mode of operation. This functionality can be turned off if a particular mode is to be forced.
The device supports both MII and RMII interface thus being more flexible and increasing the number of compatible MPU. MII and RMII options can be selected using strap options or register control. The device operates with 25-MHz clock when in MII mode and requires a 50-MHz clock when in RMII mode.
The Auto-Negotiation function provides a mechanism for exchanging configuration information between two ends of a link segment and automatically selecting the highest performance mode of operation supported by both devices. Fast Link Pulse (FLP) Bursts provide the signalling used to communicate Auto-Negotiation abilities between two devices at each end of a link segment. For further detail regarding Auto-Negotiation, refer to Clause 28 of the IEEE 802.3u specification. The DP83848Q-Q1 supports four different Ethernet protocols (10 Mb/s Half Duplex, 10 Mb/s Full Duplex, 100 Mb/s Half Duplex, and 100 Mb/s Full Duplex), so the inclusion of Auto-Negotiation ensures that the highest performance protocol will be selected based on the advertised ability of the Link Partner. The Auto-Negotiation function within the DP83848Q-Q1 can be controlled either by internal register access or by the use of the AN0 pin.
The state of AN0 determines the specific mode advertised by the DP83848Q-Q1 as given in Table 5-1. This pin allows configuration options to be selected without requiring internal register access.
The state of AN0 upon power-up/reset, determines the state of bits [8:5] of the ANAR register.
The Auto-Negotiation function selected at power-up or reset can be changed at any time by writing to the Basic Mode Control Register (BMCR) at address 0x00h.
AN0 | Advertised Mode |
---|---|
0 | 10BASE-T Half-Duplex |
100BASE-TX, Half-Duplex | |
1 | 10BASE-T, Half/Full-Duplex |
100BASE-TX, Half/Full-Duplex |
When Auto-Negotiation is enabled, the DP83848Q-Q1 transmits the abilities programmed into the Auto-Negotiation Advertisement register (ANAR) at address 04h via FLP Bursts. Any combination of 10 Mb/s, 100 Mb/s, Half-Duplex, and Full Duplex modes may be selected.
Auto-Negotiation Priority Resolution:
The Basic Mode Control Register (BMCR) at address 00h provides control for enabling, disabling, and restarting the Auto-Negotiation process. When Auto-Negotiation is disabled, the Speed Selection bit in the BMCR controls switching between 10 Mb/s or 100 Mb/s operation, and the Duplex Mode bit controls switching between full duplex operation and half duplex operation. The Speed Selection and Duplex Mode bits have no effect on the mode of operation when the Auto-Negotiation Enable bit is set.
The Link Speed can be examined through the PHY Status Register (PHYSTS) at address 10h after a Link is achieved.
The Basic Mode Status Register (BMSR) indicates the set of available abilities for technology types, Auto-Negotiation ability, and Extended Register Capability. These bits are permanently set to indicate the full functionality of the DP83848Q-Q1 (only the 100BASE-T4 bit is not set because the DP83848Q-Q1 does not support that function).
The BMSR also provides status on:
The Auto-Negotiation Advertisement Register (ANAR) indicates the Auto-Negotiation abilities to be advertised by the DP83848Q-Q1 . All available abilities are transmitted by default, but any ability can be suppressed by writing to the ANAR. Updating the ANAR to suppress an ability is one way for a management agent to change (restrict) the technology that is used.
The Auto-Negotiation Link Partner Ability Register (ANLPAR) at address 0x05h is used to receive the base link code word as well as all next page code words during the negotiation. Furthermore, the ANLPAR will be updated to either 0081h or 0021h for parallel detection to either 100 Mb/s or 10 Mb/s respectively.
The Auto-Negotiation Expansion Register (ANER) indicates additional Auto-Negotiation status. The ANER provides status on:
The DP83848Q-Q1 supports the Parallel Detection function as defined in the IEEE 802.3u specification. Parallel Detection requires both the 10 Mb/s and 100 Mb/s receivers to monitor the receive signal and report link status to the Auto-Negotiation function. Auto-Negotiation uses this information to configure the correct technology in the event that the Link Partner does not support Auto-Negotiation but is transmitting link signals that the 100BASE-TX or 10BASE-T PMAs recognize as valid link signals.
If the DP83848Q-Q1 completes Auto-Negotiation as a result of Parallel Detection, bits 5 and 7 within the ANLPAR register will be set to reflect the mode of operation present in the Link Partner. Note that bits 4:0 of the ANLPAR will also be set to 00001 based on a successful parallel detection to indicate a valid 802.3 selector field. Software may determine that negotiation completed via Parallel Detection by reading a zero in the Link Partner Auto-Negotiation Able bit once the Auto-Negotiation Complete bit is set. If configured for parallel detect mode and any condition other than a single good link occurs then the parallel detect fault bit will be set.
Once Auto-Negotiation has completed, it may be restarted at any time by setting bit 9 (Restart Auto-Negotiation) of the BMCR to one. If the mode configured by a successful Auto-Negotiation loses a valid link, then the Auto-Negotiation process will resume and attempt to determine the configuration for the link. This function ensures that a valid configuration is maintained if the cable becomes disconnected.
A renegotiation request from any entity, such as a management agent, will cause the DP83848Q-Q1 to halt any transmit data and link pulse activity until the break_link_timer expires (~1500 ms). Consequently, the Link Partner will go into link fail and normal Auto-Negotiation resumes. The DP83848Q-Q1 will resume Auto-Negotiation after the break_link_timer has expired by issuing FLP (Fast Link Pulse) bursts.
It is important to note that if the DP83848Q-Q1 has been initialized upon power-up as a non-auto-negotiating device (forced technology), and it is then required that Auto-Negotiation or re-Auto-Negotiation be initiated via software, bit 12 (Auto-Negotiation Enable) of the Basic Mode Control Register (BMCR) must first be cleared and then set for any Auto-Negotiation function to take effect.
Parallel detection and Auto-Negotiation take approximately 2-3 seconds to complete. In addition, Auto-Negotiation with next page should take approximately 2-3 seconds to complete, depending on the number of next pages sent.
Refer to Clause 28 of the IEEE 802.3u standard for a full description of the individual timers related to Auto-Negotiation.
When enabled, this function uses Auto-Negotiation to determine the proper configuration for transmission and reception of data and subsequently selects the appropriate MDI pair for MDI/MDIX operation. The function uses a random seed to control switching of the crossover circuitry. This implementation complies with the corresponding IEEE 802.3 Auto-Negotiation and Crossover Specifications.
Auto-MDIX is enabled by default and can be configured via strap or via PHYCR (19h) register, bits [15:14].
Neither Auto-Negotiation nor Auto-MDIX is required to be enabled in forcing crossover of the MDI pairs. Forced crossover can be achieved through the FORCE_MDIX bit, bit 14 of PHYCR (19h) register.
Note: Auto-MDIX will not work in a forced mode of operation.
The DP83848Q-Q1 supports a configurable Light Emitting Diode (LED) pin link and activity. The PHY Control Register (PHYCR) for the LEDs can also be selected through address 19h, bits [6:5].
See Table 5-2 for LED Mode selection.
Mode | LED_CFG (bit 5) or (pin 33) | LED_LINK |
---|---|---|
1 | 1 | ON for Good Link |
OFF for No Link | ||
2 | 0 | ON for Good Link |
BLINK for Activity |
The LED_LINK pin in Mode 1 indicates the link status of the port. In 100BASE-T mode, link is established as a result of input receive amplitude compliant with the TP-PMD specifications which will result in internal generation of signal detect. A 10 Mb/s Link is established as a result of the reception of at least seven consecutive normal Link Pulses or the reception of a valid 10BASE-T packet. This will cause the assertion of LED_LINK. LED_LINK will deassert in accordance with the Link Loss Timer as specified in the IEEE 802.3 specification.
The LED_LINK pin in Mode 1 will be OFF when no LINK is present.
The LED_LINK pin in Mode 2 will be ON to indicate Link is good and BLINK to indicate activity is present on activity.
Because the LED pin is also used as a strap option, the polarity of the LED is dependent on whether the pin is pulled up or down.
Because the Auto-Negotiation (AN) strap option shares the LED output pin, the external components required for strapping and LED usage must be considered in order to avoid contention.
Specifically, when the LED output is used to drive the LED directly, the active state of the output driver is dependent on the logic level sampled by the AN0 input upon power-up/reset. For example, if the AN0 input is resistively pulled low then the output will be configured as an active high driver. Conversely, if the AN0 input is resistively pulled high, then the output will be configured as an active low driver.
Refer to Figure 5-1 for an example of an AN0 connection to external components. In this example, the AN0 strapping results in Auto-Negotiation enabled with 10/100 Half/Full-Duplex advertised .
The adaptive nature of the LED outputs helps to simplify potential implementation issues of these dual purpose pins.
The DP83848Q-Q1 provides another option to directly control the LED output through the LED Direct Control Register (LEDCR), address 18h. The register does not provide read access to the LED.
The DP83848Q-Q1 includes a Loopback Test mode for facilitating system diagnostics. The Loopback mode is selected through bit 14 (Loopback) of the Basic Mode Control Register (BMCR). Writing 1 to this bit enables MII transmit data to be routed to the MII receive outputs. Loopback status may be checked in bit 3 of the PHY Status Register (PHYSTS). While in Loopback mode the data will not be transmitted onto the media. To ensure that the desired operating mode is maintained, Auto-Negotiation should be disabled before selecting the Loopback mode.
The DP83848Q-Q1 incorporates an internal Built-in Self Test (BIST) circuit to accommodate in-circuit testing or diagnostics. The BIST circuit can be used to test the integrity of the transmit and receive data paths. BIST testing can be performed with the part in the internal loopback mode or externally looped back using a loopback cable fixture.
The BIST is implemented with independent transmit and receive paths, with the transmit block generating a continuous stream of a pseudo random sequence. The user can select a 9 bit or 15 bit pseudo random sequence from the PSR_15 bit in the PHY Control Register (PHYCR). The received data is compared to the generated pseudo-random data by the BIST Linear Feedback Shift Register (LFSR) to determine the BIST pass/fail status.
The pass/fail status of the BIST is stored in the BIST status bit in the PHYCR register. The status bit defaults to 0 (BIST fail) and will transition on a successful comparison. If an error (mis-compare) occurs, the status bit is latched and is cleared upon a subsequent write to the Start/Stop bit.
For transmit VOD testing, the Packet BIST Continuous Mode can be used to allow continuous data transmission, setting BIST_CONT_MODE, bit 5, of CDCTRL1 (0x1Bh).
The number of BIST errors can be monitored through the BIST Error Count in the CDCTRL1 (0x1Bh), bits [15:8].
When Energy Detect is enabled and there is no activity on the cable, the DP83848Q-Q1 will remain in a low power mode while monitoring the transmission line. Activity on the line will cause the DP83848Q-Q1 to go through a normal power up sequence. Regardless of cable activity, the DP83848Q-Q1 will occasionally wake up the transmitter to put ED pulses on the line, but will otherwise draw as little power as possible. Energy detect functionality is controlled via register Energy Detect Control (EDCR), address 0x1Dh.
The DP83848Q-Q1 supports two modes of operation using the MII interface pins. The options are defined in the following sections and include:
The modes of operation can be selected by strap options or register control. For RMII mode, it is required to use the strap option, because it requires a 50 MHz clock instead of the normal 25 MHz.
In each of these modes, the IEEE 802.3 serial management interface is operational for device configuration and status. The serial management interface of the MII allows for the configuration and control of multiple PHY devices, gathering of status, error information, and the determination of the type and capabilities of the attached PHY(s).
The DP83848Q-Q1 incorporates the Media Independent Interface (MII) as specified in Clause 22 of the IEEE 802.3u standard. This interface may be used to connect PHY devices to a MAC in 10/100 Mb/s systems. This section describes the nibble wide MII data interface.
The nibble wide MII data interface consists of a receive bus and a transmit bus each with control signals to facilitate data transfer between the PHY and the upper layer (MAC).
Clause 22 of the IEEE 802.3u specification defines the Media Independent Interface. This interface includes a dedicated receive bus and a dedicated transmit bus. These two data buses, along with various control and status signals, allow for the simultaneous exchange of data between the DP83848Q-Q1 and the upper layer agent (MAC).
The receive interface consists of a nibble wide data bus RXD[3:0], a receive error signal RX_ER, a receive data valid flag RX_DV, and a receive clock RX_CLK for synchronous transfer of the data. The receive clock operates at either 2.5 MHz to support 10 Mb/s operation modes or at 25 MHz to support 100 Mb/s operational modes.
The transmit interface consists of a nibble wide data bus TXD[3:0], a transmit enable control signal TX_EN, and a transmit clock TX_CLK which runs at either 2.5 MHz or 25 MHz.
Additionally, the MII includes the carrier sense signal CRS, as well as a collision detect signal COL. The CRS signal asserts to indicate the reception of data from the network or as a function of transmit data in Half Duplex mode. The COL signal asserts as an indication of a collision which can occur during half-duplex operation when both a transmit and receive operation occur simultaneously.
For Half Duplex, a 10BASE-T or 100BASE-TX collision is detected when the receive and transmit channels are active simultaneously. Collisions are reported by the COL signal on the MII.
If the DP83848Q-Q1 is transmitting in 10 Mb/s mode when a collision is detected, the collision is not reported until seven bits have been received while in the collision state. This prevents a collision being reported incorrectly due to noise on the network. The COL signal remains set for the duration of the collision.
If a collision occurs during a receive operation, it is immediately reported by the COL signal.
When heartbeat is enabled (only applicable to 10 Mb/s operation), approximately 1µs after the transmission of each packet, a Signal Quality Error (SQE) signal of approximately 10 bit times is generated (internally) to indicate successful transmission. SQE is reported as a pulse on the COL signal of the MII.
Carrier Sense (CRS) is asserted due to receive activity, once valid data is detected via the squelch function during 10 Mb/s operation. During 100 Mb/s operation CRS is asserted when a valid link (SD) and two non-contiguous zeros are detected on the line.
For 10 or 100 Mb/s Half Duplex operation, CRS is asserted during either packet transmission or reception.
For 10 or 100 Mb/s Full Duplex operation, CRS is asserted only due to receive activity.
CRS is deasserted following an end of packet.
The DP83848Q-Q1 incorporates the Reduced Media Independent Interface (RMII) as specified in the RMII specification (rev1.2) from the RMII Consortium. This interface may be used to connect PHY devices to a MAC in 10/100 Mb/s systems using a reduced number of pins. In this mode, data is transferred 2-bits at a time using the 50 MHz RMII_REF clock for both transmit and receive. The following pins are used in RMII mode:
In addition, the RMII mode supplies an RX_DV signal which allows for a simpler method of recovering receive data without having to separate RX_DV from the CRS_DV indication. This is especially useful for diagnostic testing where it may be desirable to externally loop Receive MII data directly to the transmitter.
Because the reference clock operates at 10 times the data rate for 10 Mb/s operation, transmit data is sampled every 10 clocks. Likewise, receive data will be generated every 10th clock so that an attached device can sample the data every 10 clocks.
RMII mode requires a 50-MHz oscillator be connected to the device X1 pin. A 50 MHz crystal is not supported.
To tolerate potential frequency differences between the 50-MHz reference clock and the recovered receive clock, the receive RMII function includes a programmable elasticity buffer. The elasticity buffer is programmable to minimize propagation delay based on expected packet size and clock accuracy. This allows for supporting a range of packet sizes including jumbo frames.
The elasticity buffer will force Frame Check Sequence errors for packets which overrun or underrun the FIFO. Underrun and Overrun conditions can be reported in the RMII and Bypass Register (RBR). Table 5-3 indicates how to program the elasticity buffer fifo (in 4-bit increments) based on expected max packet size and clock accuracy. It assumes both clocks (RMII Reference clock and far-end Transmitter clock) have the same accuracy.
Start Threshold RBR[1:0] | Latency Tolerance | Recommended Packet Size at ±50ppm |
Recommended Packet Size at ±100ppm |
---|---|---|---|
1 (4-bits) | 2 bits | 2,400 bytes | 1,200 bytes |
2 (8-bits) | 6 bits | 7,200 bytes | 3,600 bytes |
3 (12-bits) | 10 bits | 12,000 bytes | 6,000 bytes |
0 (16-bits) | 14 bits | 16,800 bytes | 8,400 bytes |
The serial management MII specification defines a set of thirty-two 16-bit status and control registers that are accessible through the management interface pins MDC and MDIO. The DP83848Q-Q1 implements all the required MII registers as well as several optional registers. These registers are fully described in Section 5.6.
The serial control interface consists of two pins, Management Data Clock (MDC) and Management Data Input/Output (MDIO). MDC has a maximum clock rate of 25 MHz and no minimum rate. The MDIO line is bi-directional and may be shared by up to 32 devices. The MDIO frame format is shown below in Table 5-4.
MII Management Serial Protocol | <idle><start><op code><device addr><reg addr><turnaround><data><idle> |
---|---|
Read Operation | <idle><01><10><AAAAA><RRRRR><Z0><xxxx xxxx xxxx xxxx><idle> |
Write Operation | <idle><01><01><AAAAA><RRRRR><10><xxxx xxxx xxxx xxxx><idle> |
The MDIO pin requires a pull-up resistor (1.5 kΩ) which, during IDLE and turnaround, will pull MDIO high. In order to initialize the MDIO interface, the station management entity sends a sequence of 32 contiguous logic ones on MDIO to provide the DP83848Q-Q1 with a sequence that can be used to establish synchronization. This preamble may be generated either by driving MDIO high for 32 consecutive MDC clock cycles, or by simply allowing the MDIO pull-up resistor to pull the MDIO pin high during which time 32 MDC clock cycles are provided. In addition 32 MDC clock cycles should be used to re-sync the device if an invalid start, opcode, or turnaround bit is detected.
The DP83848Q-Q1 waits until it has received this preamble sequence before responding to any other transaction. Once the DP83848Q-Q1 serial management port has been initialized no further preamble sequencing is required until after a power-on/reset, invalid Start, invalid Opcode, or invalid turnaround bit has occurred.
The Start code is indicated by a <01> pattern. This assures the MDIO line transitions from the default idle line state.
Turnaround is defined as an idle bit time inserted between the Register Address field and the Data field. To avoid contention during a read transaction, no device shall actively drive the MDIO signal during the first bit of Turnaround. The addressed DP83848Q-Q1 drives the MDIO with a zero for the second bit of turnaround and follows this with the required data. Figure 5-2 shows the timing relationship between MDC and the MDIO as driven/received by the Station (STA) and the DP83848Q-Q1 (PHY) for a typical register read access.
For write transactions, the station management entity writes data to the addressed DP83848Q-Q1 thus eliminating the requirement for MDIO Turnaround. The Turnaround time is filled by the management entity by inserting <10>. Figure 5-3 shows the timing relationship for a typical MII register write access.
The DP83848Q-Q1 supports a Preamble Suppression mode as indicated by a one in bit 6 of the Basic Mode Status Register (BMSR, address 01h.) If the station management entity (i.e. MAC or other management controller) determines that all PHYs in the system support Preamble Suppression by returning a one in this bit, then the station management entity need not generate preamble for each management transaction.
The DP83848Q-Q1 requires a single initialization sequence of 32 bits of preamble following hardware/software reset. This requirement is generally met by the mandatory pull-up resistor on MDIO in conjunction with a continuous MDC, or the management access made to determine whether Preamble Suppression is supported.
While the DP83848Q-Q1 requires an initial preamble sequence of 32 bits for management initialization, it does not require a full 32-bit sequence between each subsequent transaction. A minimum of one idle bit between management transactions is required as specified in the IEEE 802.3u specification.
The 5 PHY address inputs pins are shared with the RXD[3:0] pins and COL pin are shown below.
Pin No. | PHYAD Function | RXD Function |
---|---|---|
42 | PHYAD0 | COL |
43 | PHYAD1 | RXD_0 |
44 | PHYAD2 | RXD_1 |
45 | PHYAD3 | RXD_2 |
46 | PHYAD4 | RXD_3 |
The DP83848Q-Q1 can be set to respond to any of 32 possible PHY addresses via strap pins. The information is latched into the PHYCR register (address 19h, bits [4:0]) at device power-up and hardware reset. The PHY Address pins are shared with the RXD and COL pins. Each DP83848Q-Q1 or port sharing an MDIO bus in a system must have a unique physical address.
The DP83848Q-Q1 supports PHY Address strapping values 0 (<00000>) through 31 (<11111>). Strapping PHY Address 0 puts the part into Isolate Mode. It should also be noted that selecting PHY Address 0 via an MDIO write to PHYCR will not put the device in Isolate Mode. See Section 5.4.4.1 for more information.
For further detail relating to the latch-in timing requirements of the PHY Address pins, as well as the other hardware configuration pins, refer to the Reset summary in Section 5.4.6.
Because the PHYAD[0] pin has weak internal pull-up resistor and PHYAD[4:1] pins have weak internal pull-down resistors, the default setting for the PHY address is 00001 (0x01h).
Refer to Figure 5-4 for an example of a PHYAD connection to external components. In this example, the PHYAD strapping results in address 000101 (0x03h).
The DP83848Q-Q1 can be put into MII Isolate mode by writing to bit 10 of the BMCR register or by strapping in Physical Address 0. It should be noted that selecting Physical Address 0 via an MDIO write to PHYCR will not put the device in the MII isolate mode.
When in the MII isolate mode, the DP83848Q-Q1 does not respond to packet data present at TXD[3:0], TX_EN inputs and presents a high impedance on the TX_CLK, RX_CLK, RX_DV, RX_ER, RXD[3:0], COL, and CRS outputs. When in Isolate mode, the DP83848Q-Q1 will continue to respond to all management transactions.
While in Isolate mode, the PMD output pair will not transmit packet data but will continue to source 100BASE-TX scrambled idles or 10BASE-T normal link pulses.
The DP83848Q-Q1 can Auto-Negotiate or parallel detect to a specific technology depending on the receive signal at the PMD input pair. A valid link can be established for the receiver even when the DP83848Q-Q1 is in Isolate mode.
The DP83848Q-Q1 supports both half and full duplex operation at both 10 Mb/s and 100 Mb/s speeds.
Half-duplex relies on the CSMA/CD protocol to handle collisions and network access. In Half-Duplex mode, CRS responds to both transmit and receive activity in order to maintain compliance with the IEEE 802.3 specification.
Because the DP83848Q-Q1 is designed to support simultaneous transmit and receive activity, it is capable of supporting full-duplex switched applications with a throughput of up to 200 Mb/s per port when operating in 100BASE-TX. CSMA/CD protocol does not apply to full-duplex operation so DP83848Q-Q1 disables its own internal collision sensing and reporting functions and modifies the behavior of Carrier Sense (CRS) such that it indicates only receive activity. This allows a full-duplex capable MAC to operate properly.
All modes of operation (100BASE-TX and 10BASE-T) can run either half-duplex or full-duplex. Additionally, other than CRS and Collision reporting, all remaining MII signaling remains the same regardless of the selected duplex mode.
It is important to understand that while Auto-Negotiation with the use of Fast Link Pulse code words can interpret and configure to full-duplex operation, parallel detection can not recognize the difference between full and half-duplex from a fixed 10 Mb/s or 100 Mb/s link partner over twisted pair. As specified in the 802.3u specification, if a far-end link partner is configured to a forced full duplex 100BASE-TX ability, the parallel detection state machine in the partner would be unable to detect the full duplex capability of the far-end link partner. This link segment would negotiate to a half duplex 100BASE-TX configuration (same scenario for 10 Mb/s).
The DP83848Q-Q1 includes an internal power-on reset (POR) function and does not need to be explicitly reset for normal operation after power up. If required during normal operation, the device can be reset by a hardware or software reset.
A hardware reset is accomplished by applying a low pulse (TTL level), with a duration of at least 1 µs, to the RESET_N pin. This will reset the device such that all registers will be reinitialized to default values and the hardware configuration values will be re-latched into the device (similar to the power-up/reset operation).
A software reset is accomplished by setting the reset bit (bit 15) of the Basic Mode Control Register (BMCR). The period from the point in time when the reset bit is set to the point in time when software reset has concluded is approximately 1 µs.
A software reset will reset the device such that all the registers will be re-initialized to default values and the hardware configuration values will be re-latched into the device. Software driver code must wait 3 µs following a software reset before allowing further serial MII operations with the DP83848Q-Q1
This section describes the operations within each transceiver module, 100BASE-TX and 10BASE-T. Each operation consists of several functional blocks and described in the following:
The 100BASE-TX transmitter consists of several functional blocks which convert synchronous 4-bit nibble data, as provided by the MII, to a scrambled MLT-3 125 Mb/s serial data stream. Because the 100BASE-TX TP-PMD is integrated, the differential output pins, PMD Output Pair, can be directly routed to the magnetics. The block diagram in Figure 5-5. provides an overview of each functional block within the 100BASE-TX transmit section.
The Transmitter section consists of the following functional blocks:
The bypass option for the functional blocks within the 100BASE-TX transmitter provides flexibility for applications where data conversion is not always required. The DP83848Q-Q1 implements the 100BASE-TX transmit state machine diagram as specified in the IEEE 802.3u Standard, Clause 24.
DATA CODES | ||
---|---|---|
0 | 11110 | 0000 |
1 | 01001 | 0001 |
2 | 10100 | 0010 |
3 | 10101 | 0011 |
4 | 01010 | 0100 |
5 | 01011 | 0101 |
6 | 01110 | 0110 |
7 | 01111 | 0111 |
8 | 10010 | 1000 |
9 | 10011 | 1001 |
A | 10110 | 1010 |
B | 10111 | 1011 |
C | 11010 | 1100 |
D | 11011 | 1101 |
E | 11100 | 1110 |
F | 11101 | 1111 |
IDLE AND CONTROL CODES | ||
H | 00100 | HALT code-group - Error code |
I | 11111 | Inter-Packet IDLE - 0000(1) |
J | 11000 | First Start of Packet - 0101(1) |
K | 10001 | Second Start of Packet - 0101(1) |
T | 01101 | First End of Packet - 0000(1) |
R | 00111 | Second End of Packet - 0000(1) |
INVALID CODES | ||
V | 00000 | |
V | 00001 | |
V | 00010 | |
V | 00011 | |
V | 00101 | |
V | 00110 | |
V | 01000 | |
V | 01100 |
The code-group encoder converts 4-bit (4B) nibble data generated by the MAC into 5-bit (5B) code-groups for transmission. This conversion is required to allow control data to be combined with packet data code-groups. See Table 5-6 for 4B to 5B code-group mapping details.
The code-group encoder substitutes the first 8-bits of the MAC preamble with a J/K code-group pair (11000 10001) upon transmission. The code-group encoder continues to replace subsequent 4B preamble and data nibbles with corresponding 5B code-groups. At the end of the transmit packet, upon the deassertion of Transmit Enable signal from the MAC, the code-group encoder injects the T/R code-group pair (01101 00111) indicating the end of the frame.
After the T/R code-group pair, the code-group encoder continuously injects IDLEs into the transmit data stream until the next transmit packet is detected (reassertion of Transmit Enable).
The scrambler is required to control the radiated emissions at the media connector and on the twisted-pair cable (for 100BASE-TX applications). By scrambling the data, the total energy launched onto the cable is randomly distributed over a wide frequency range. Without the scrambler, energy levels at the PMD and on the cable could peak beyond FCC limitations at frequencies related to repeating 5B sequences (that is, continuous transmission of IDLEs).
The scrambler is configured as a closed loop linear feedback shift register (LFSR) with an 11-bit polynomial. The output of the closed loop LFSR is X-ORd with the serial NRZ data from the code-group encoder. The result is a scrambled data stream with sufficient randomization to decrease radiated emissions at certain frequencies by as much as 20 dB. The DP83848Q-Q1 uses the PHY_ID (pins PHYAD [4:1]) to set a unique seed value.
After the transmit data stream has been serialized and scrambled, the data must be NRZI encoded in order to comply with the TP-PMD standard for 100BASE-TX transmission over Category-5 Unshielded twisted-pair cable.
The Binary to MLT-3 conversion is accomplished by converting the serial binary data stream output from the NRZI encoder into two binary data streams with alternately phased logic one events. These two binary streams are then fed to the twisted-pair output driver which converts the voltage to current and alternately drives either side of the transmit transformer primary winding, resulting in a MLT-3 signal.
The 100BASE-TX MLT-3 signal sourced by the PMD Output Pair common driver is slew rate controlled. This should be considered when selecting AC coupling magnetics to ensure TP-PMD Standard compliant transition times (3 ns < Tr < 5 ns).
The 100BASE-TX transmit TP-PMD function within the DP83848Q-Q1 is capable of sourcing only MLT-3 encoded data. Binary output from the PMD Output Pair is not possible in 100 Mb/s mode.
The 100BASE-TX receiver consists of several functional blocks which convert the scrambled MLT-3 125 Mb/s serial data stream to synchronous 4-bit nibble data that is provided to the MII. Because the 100BASE-TX TP-PMD is integrated, the differential input pins, RD±, can be directly routed from the AC coupling magnetics.
See Figure 5-6 for a block diagram of the 100BASE-TX receive function. This provides an overview of each functional block within the 100BASE-TX receive section.
The Receive section consists of the following functional blocks:
In addition to the Digital Equalization and Gain Control, the DP83848Q-Q1 includes Analog Equalization and Gain Control in the Analog Front End. The Analog Equalization reduces the amount of Digital Equalization required in the DSP.
The Digital Signal Processor includes Adaptive Equalization with Gain Control and Base Line Wander Compensation.
When transmitting data at high speeds over copper twisted-pair cable, frequency dependent attenuation becomes a concern. In high-speed twisted-pair signalling, the frequency content of the transmitted signal can vary greatly during normal operation based primarily on the randomness of the scrambled data stream. This variation in signal attenuation caused by frequency variations must be compensated to ensure the integrity of the transmission.
To ensure quality transmission when employing MLT-3 encoding, the compensation must be able to adapt to various cable lengths and cable types depending on the installed environment. The selection of long cable lengths for a given implementation, requires significant compensation which will over-compensate for shorter, less attenuating lengths. Conversely, the selection of short or intermediate cable lengths requiring less compensation will cause serious under-compensation for longer length cables. The compensation or equalization must be adaptive to ensure proper conditioning of the received signal independent of the cable length.
The DP83848Q-Q1 uses an extremely robust equalization scheme referred as ‘Digital Adaptive Equalization.’
The Digital Equalizer removes ISI (inter symbol interference) from the receive data stream by continuously adapting to provide a filter with the inverse frequency response of the channel. Equalization is combined with an adaptive gain control stage. This enables the receive 'eye pattern' to be opened sufficiently to allow very reliable data recovery.
The curves given in Figure 5-8 illustrate attenuation at certain frequencies for given cable lengths. This is derived from the worst case frequency vs. attenuation figures as specified in the EIA/TIA Bulletin TSB-36. These curves indicate the significant variations in signal attenuation that must be compensated for by the receive adaptive equalization circuit.
The DP83848Q-Q1 is completely ANSI TP-PMD compliant and includes Base Line Wander (BLW) compensation. The BLW compensation block can successfully recover the TP-PMD defined “killer” pattern.
BLW can generally be defined as the change in the average DC content, relatively short period over time, of an AC coupled digital transmission over a given transmission medium. (that is, copper wire).
BLW results from the interaction between the low frequency components of a transmitted bit stream and the frequency response of the AC coupling component(s) within the transmission system. If the low frequency content of the digital bit stream goes below the low frequency pole of the AC coupling transformers then the droop characteristics of the transformers will dominate resulting in potentially serious BLW.
The digital oscilloscope plot provided in Figure 5-9 illustrates the severity of the BLW event that can theoretically be generated during 100BASE-TX packet transmission. This event consists of approximately 800 mV of DC offset for a period of 120 ms. Left uncompensated, events such as this can cause packet loss.
The signal detect function of the DP83848Q-Q1 is incorporated to meet the specifications mandated by the ANSI FDDI TP-PMD Standard as well as the IEEE 802.3 100BASE-TX Standard for both voltage thresholds and timing parameters.
Note that the reception of normal 10BASE-T link pulses and fast link pulses per IEEE 802.3u Auto-Negotiation by the 100BASE-TX receiver do not cause the DP83848Q-Q1 to assert signal detect.
The DP83848Q-Q1 decodes the MLT-3 information from the Digital Adaptive Equalizer block to binary NRZI data.
In a typical application, the NRZI to NRZ decoder is required in order to present NRZ formatted data to the descrambler.
The 100BASE-TX receiver includes a Serial to Parallel converter which supplies 5-bit wide data symbols to the PCS Rx state machine.
A serial descrambler is used to de-scramble the received NRZ data. The descrambler has to generate an identical data scrambling sequence (N) in order to recover the original unscrambled data (UD) from the scrambled data (SD) as represented in the equations:
Synchronization of the descrambler to the original scrambling sequence (N) is achieved based on the knowledge that the incoming scrambled data stream consists of scrambled IDLE data. After the descrambler has recognized 12 consecutive IDLE code-groups, where an unscrambled IDLE code-group in 5B NRZ is equal to five consecutive ones (11111), it will synchronize to the receive data stream and generate unscrambled data in the form of unaligned 5B code-groups.
In order to maintain synchronization, the descrambler must continuously monitor the validity of the unscrambled data that it generates. To ensure this, a line state monitor and a hold timer are used to constantly monitor the synchronization status. Upon synchronization of the descrambler the hold timer starts a 722 µs countdown. Upon detection of sufficient IDLE code-groups (58 bit times) within the 722 µs period, the hold timer will reset and begin a new countdown. This monitoring operation will continue indefinitely given a properly operating network connection with good signal integrity. If the line state monitor does not recognize sufficient unscrambled IDLE code-groups within the 722 µs period, the entire descrambler will be forced out of the current state of synchronization and reset in order to re-acquire synchronization.
The code-group alignment module operates on unaligned 5-bit data from the descrambler (or, if the descrambler is bypassed, directly from the NRZI/NRZ decoder) and converts it into 5B code-group data (5 bits). Code-group alignment occurs after the J/K code-group pair is detected. Once the J/K code-group pair (11000 10001) is detected, subsequent data is aligned on a fixed boundary.
The code-group decoder functions as a look up table that translates incoming 5B code-groups into 4B nibbles. The code-group decoder first detects the J/K code-group pair preceded by IDLE code-groups and replaces the J/K with MAC preamble. Specifically, the J/K 10-bit code-group pair is replaced by the nibble pair (0101 0101). All subsequent 5B code-groups are converted to the corresponding 4B nibbles for the duration of the entire packet. This conversion ceases upon the detection of the T/R code-group pair denoting the End of Stream Delimiter (ESD) or with the reception of a minimum of two IDLE code-groups.
The 100 Base TX Link monitor ensures that a valid and stable link is established before enabling both the Transmit and Receive PCS layer.
Signal detect must be valid for 395us to allow the link monitor to enter the 'Link Up' state, and enable the transmit and receive functions.
A Bad Start of Stream Delimiter (Bad SSD) is any transition from consecutive idle code-groups to non-idle code-groups which is not prefixed by the code-group pair /J/K.
If this condition is detected, the DP83848Q-Q1 will assert RX_ER and present RXD[3:0] = 1110 to the MII for the cycles that correspond to received 5B code-groups until at least two IDLE code groups are detected. In addition, the False Carrier Sense Counter register (FCSCR) will be incremented by one.
Once at least two IDLE code groups are detected, RX_ER and CRS become de-asserted.
The 10BASE-T Transceiver Module is IEEE 802.3 compliant. It includes the receiver, transmitter, collision, heartbeat, loopback, jabber, and link integrity functions, as defined in the standard. An external filter is not required on the 10BASE-T interface because this is integrated inside the DP83848Q-Q1 . This section focuses on the general 10BASE-T system level operation.
The DP83848Q-Q1 has two basic 10BASE-T operational modes:
In Half Duplex mode the DP83848Q-Q1 functions as a standard IEEE 802.3 10BASE-T transceiver supporting the CSMA/CD protocol.
In Full Duplex mode the DP83848Q-Q1 can simultaneously transmit and receive without asserting the collision signal. The 10 Mb/s ENDEC is designed to encode and decode simultaneously.
The smart squelch is responsible for determining when valid data is present on the differential receive inputs. The DP83848Q-Q1 implements an intelligent receive squelch to ensure that impulse noise on the receive inputs will not be mistaken for a valid signal. Smart squelch operation is independent of the 10BASE-T operational mode.
The squelch circuitry employs a combination of amplitude and timing measurements (as specified in the IEEE 802.3 10BSE-T standard) to determine the validity of data on the twisted-pair inputs (see Figure 5-9).
The signal at the start of a packet is checked by the smart squelch and any pulses not exceeding the squelch level (either positive or negative, depending upon polarity) will be rejected. Once this first squelch level is overcome correctly, the opposite squelch level must then be exceeded within 150 ns. Finally the signal must again exceed the original squelch level within 150 ns to ensure that the input waveform will not be rejected. This checking procedure results in the loss of typically three preamble bits at the beginning of each packet.
Only after all these conditions have been satisfied will a control signal be generated to indicate to the remainder of the circuitry that valid data is present. At this time, the smart squelch circuitry is reset.
Valid data is considered to be present until the squelch level has not been generated for a time longer than 150 ns, indicating the End of Packet. Once good data has been detected, the squelch levels are reduced to minimize the effect of noise causing premature End of Packet detection.
When in Half Duplex, a 10BASE-T collision is detected when the receive and transmit channels are active simultaneously. Collisions are reported by the COL signal on the MII. Collisions are also reported when a jabber condition is detected.
The COL signal remains set for the duration of the collision. If the PHY is receiving when a collision is detected it is reported immediately (through the COL pin).
When heartbeat is enabled, approximately 1 µs after the transmission of each packet, a Signal Quality Error (SQE) signal of approximately 10-bit times is generated to indicate successful transmission. SQE is reported as a pulse on the COL signal of the MII.
The SQE test is inhibited when the PHY is set in full duplex mode. SQE can also be inhibited by setting the HEARTBEAT_DIS bit in the 10BTSCR register.
Carrier Sense (CRS) may be asserted due to receive activity once valid data is detected via the squelch function.
For 10 Mb/s Half Duplex operation, CRS is asserted during either packet transmission or reception.
For 10 Mb/s Full Duplex operation, CRS is asserted only during receive activity.
CRS is deasserted following an end of packet.
The link pulse generator produces pulses as defined in the IEEE 802.3 10BASE-T standard. Each link pulse is nominally 100 ns in duration and transmitted every 16 ms in the absence of transmit data.
Link pulses are used to check the integrity of the connection with the remote end. If valid link pulses are not received, the link detector disables the 10BASE-T twisted-pair transmitter, receiver and collision detection functions.
When the link integrity function is disabled (FORCE_LINK_10 of the 10BTSCR register), a good link is forced and the 10BASE-T transceiver will operate regardless of the presence of link pulses.
The jabber function monitors the output of DP83848Q-Q1 and disables the transmitter if it tries to transmit a packet of longer than legal size. A jabber timer monitors the transmitter and disables the transmission if the transmitter is active for approximately 85 ms.
Once disabled by the Jabber function, the transmitter stays disabled for the entire time that the ENDEC module's internal transmit enable is asserted. This signal has to be de-asserted for approximately 500 ms (the “unjab” time) before the Jabber function re-enables the transmit outputs.
The Jabber function is only relevant in 10BASE-T mode.
The DP83848Q-Q1's 10BASE-T transceiver module incorporates an automatic link polarity detection circuit. When three consecutive inverted link pulses are received, bad polarity is reported.
A polarity reversal can be caused by a wiring error at either end of the cable, usually at the Main Distribution Frame (MDF) or patch panel in the wiring closet.
The bad polarity condition is latched in the 10BTSCR register. The DP83848Q-Q1's 10BASE-T transceiver module corrects for this error internally and will continue to decode received data correctly. This eliminates the need to correct the wiring error immediately.
External 10BASE-T filters are not required when using the DP83848Q-Q1, as the required signal conditioning is integrated into the device.
Only isolation transformers and impedance matching resistors are required for the 10BASE-T transmit and receive interface. The internal transmit filtering ensures that all the harmonics in the transmit signal are attenuated by at least 30 dB.
The encoder begins operation when the Transmit Enable input (TX_EN) goes high and converts NRZ data to pre-emphasized Manchester data for the transceiver. For the duration of TX_EN, the serialized Transmit Data (TXD) is encoded for the transmit-driver pair (PMD Output Pair). TXD must be valid on the rising edge of Transmit Clock (TX_CLK). Transmission ends when TX_EN deasserts. The last transition is always positive; it occurs at the center of the bit cell if the last bit is a one, or at the end of the bit cell if the last bit is a zero.
The decoder detects the end of a frame when no additional mid-bit transitions are detected. Within one and a half bit times after the last bit, carrier sense is de-asserted. Receive clock stays active for five more bit times after CRS goes low, to ensure the receive timings of the controller.
OFFSET | ACCESS | TAG | DESCRIPTION | |
---|---|---|---|---|
HEX | DECIMAL | |||
00h | 0 | RW | BMCR | Basic Mode Control Register |
01h | 1 | RO | BMSR | Basic Mode Status Register |
02h | 2 | RO | PHYIDR1 | PHY Identifier Register #1 |
03h | 3 | RO | PHYIDR2 | PHY Identifier Register #2 |
04h | 4 | RW | ANAR | Auto-Negotiation Advertisement Register |
05h | 5 | RW | ANLPAR | Auto-Negotiation Link Partner Ability Register (Base Page) |
05h | 5 | RW | ANLPARNP | Auto-Negotiation Link Partner Ability Register (Next Page) |
06h | 6 | RW | ANER | Auto-Negotiation Expansion Register |
07h | 7 | RW | ANNPTR | Auto-Negotiation Next Page TX |
08h - Fh | 8 - 15 | RESERVED | RESERVED | |
EXTENDED REGISTERS | ||||
10h | 16 | RO | PHYSTS | PHY Status Register |
11h - 13h | 17 - 19 | RO | RESERVED | RESERVED |
14h | 20 | RO | FCSCR | False Carrier Sense Counter Register |
15h | 21 | RO | RECR | Receive Error Counter Register |
16h | 22 | RW | PCSR | PCS Sub-Layer Configuration and Status Register |
17h | 23 | RW | RBR | RMII and Bypass Register |
18h | 24 | RW | LEDCR | LED Direct Control Register |
19h | 25 | RW | PHYCR | PHY Control Register |
1Ah | 26 | RW | 10BTSCR | 10Base-T Status/Control Register |
1Bh | 27 | RW | CDCTRL1 | CD Test Control Register and BIST Extensions Register |
1Ch | 28 | RW | RESERVED | RESERVED |
1Dh | 29 | RW | EDCR | Energy Detect Control Register |
1Eh - 1Fh | 30 - 31 | RW | RESERVED | RESERVED |
In the register definitions under the ‘Default’ heading, the following definitions hold true:
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15 | 100BASE-T4 | 0, RO/P | 100BASE-T4 Capable: |
0 = Device not able to perform 100BASE-T4 mode. | |||
14 | 100BASE-TX | 1, RO/P | 100BASE-TX Full Duplex Capable: |
FULL DUPLEX | 1 = Device able to perform 100BASE-TX in full duplex mode. | ||
13 | 100BASE-TX | 1, RO/P | 100BASE-TX Half Duplex Capable: |
HALF DUPLEX | 1 = Device able to perform 100BASE-TX in half duplex mode. | ||
12 | 10BASE-T | 1, RO/P | 10BASE-T Full Duplex Capable: |
FULL DUPLEX | 1 = Device able to perform 10BASE-T in full duplex mode. | ||
11 | 10BASE-T | 1, RO/P | 10BASE-T Half Duplex Capable: |
HALF DUPLEX | 1 = Device able to perform 10BASE-T in half duplex mode. | ||
10:7 | RESERVED | 0, RO | RESERVED: Write as 0, read as 0. |
6 | MF PREAMBLE | 1, RO/P | Preamble suppression Capable: |
SUPPRESSION | 1 = Device able to perform management transaction with preamble suppressed, 32-bits of preamble needed only once after reset, invalid opcode or invalid turnaround. | ||
0 = Normal management operation. | |||
5 | AUTO-NEGOTIATION COMPLETE | 0, RO | Auto-Negotiation Complete: |
1 = Auto-Negotiation process complete. | |||
0 = Auto-Negotiation process not complete. | |||
4 | REMOTE FAULT | 0, RO/LH | Remote Fault: |
1 = Remote Fault condition detected (cleared on read or by reset). Fault criteria: Notification from Link Partner of Remote Fault. | |||
0 = No remote fault condition detected. | |||
3 | AUTO-NEGOTIATION ABILITY | 1, RO/P | Auto Negotiation Ability: |
1 = Device is able to perform Auto-Negotiation. | |||
0 = Device is not able to perform Auto-Negotiation. | |||
2 | LINK STATUS | 0, RO/LL | Link Status: |
1 = Valid link established (for either 10 or 100 Mb/s operation). | |||
0 = Link not established. | |||
The criteria for link validity is implementation specific. The occurrence of a link failure condition will causes the Link Status bit to clear. Once cleared, this bit may only be set by establishing a good link condition and a read via the management interface. | |||
1 | JABBER DETECT | 0, RO/LH | Jabber Detect: This bit only has meaning in 10 Mb/s mode. |
1 = Jabber condition detected. | |||
0 = No Jabber. | |||
This bit is implemented with a latching function, such that the occurrence of a jabber condition causes it to set until it is cleared by a read to this register by the management interface or by a reset. | |||
0 | EXTENDED CAPABILITY | 1, RO/P | Extended Capability: |
1 = Extended register capabilities. | |||
0 = Basic register set capabilities only. |
The PHY Identifier Registers #1 and #2 together form a unique identifier for the DP83848Q-Q1 . The Identifier consists of a concatenation of the Organizationally Unique Identifier (OUI), the vendor's model number and the model revision number. A PHY may return a value of zero in each of the 32 bits of the PHY Identifier if desired. The PHY Identifier is intended to support network management. TI's IEEE assigned OUI is 080017h.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15:0 | OUI_MSB | <0010 0000 0000 0000>, RO/P | OUI Most Significant Bits: Bits 3 to 18 of the OUI (080017h) are stored in bits 15 to 0 of this register. The most significant two bits of the OUI are ignored (the IEEE standard refers to these as bits 1 and 2). |
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15:10 | OUI_LSB | <0101 11>, RO/P | OUI Least Significant Bits: |
Bits 19 to 24 of the OUI (080017h) are mapped from bits 15 to 10 of this register respectively. | |||
9:4 | VNDR_MDL | <00 1010>, RO/P | Vendor Model Number: |
The six bits of vendor model number are mapped from bits 9 to 4 (most significant bit to bit 9). | |||
3:0 | MDL_REV | <0010>, RO/P | Model Revision Number: |
Four bits of the vendor model revision number are mapped from bits 3 to 0 (most significant bit to bit 3). This field will be incremented for all major device changes. |
This register contains the advertised abilities of this device as they will be transmitted to its link partner during Auto-Negotiation.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15 | NP | 0, RW | Next Page Indication: |
0 = Next Page Transfer not desired. | |||
1 = Next Page Transfer desired. | |||
14 | RESERVED | 0, RO/P | RESERVED by IEEE: Writes ignored, read as 0. |
13 | RF | 0, RW | Remote Fault: |
1 = Advertises that this device has detected a Remote Fault. | |||
0 = No Remote Fault detected. | |||
12 | RESERVED | 0, RW | RESERVED for Future IEEE use: Write as 0, Read as 0 |
11 | ASM_DIR | 0, RW | Asymmetric PAUSE Support for Full Duplex Links: |
The ASM_DIR bit indicates that asymmetric PAUSE is supported. | |||
Encoding and resolution of PAUSE bits is defined in IEEE 802.3 Annex 28B, Tables 28B-2 and 28B-3, respectively. Pause resolution status is reported in PHYCR[13:12]. | |||
1 = Advertise that the DTE (MAC) has implemented both the optional MAC control sublayer and the pause function as specified in clause 31 and annex 31B of 802.3u. | |||
0= No MAC based full duplex flow control. | |||
10 | PAUSE | 0, RW | PAUSE Support for Full Duplex Links: |
The PAUSE bit indicates that the device is capable of providing the symmetric PAUSE functions as defined in Annex 31B. | |||
Encoding and resolution of PAUSE bits is defined in IEEE 802.3 Annex 28B, Tables 28B-2 and 28B-3, respectively. Pause resolution status is reported in PHYCR[13:12]. | |||
1 = Advertise that the DTE (MAC) has implemented both the optional MAC control sublayer and the pause function as specified in clause 31 and annex 31B of 802.3u. | |||
0= No MAC based full duplex flow control. | |||
9 | T4 | 0, RO/P | 100BASE-T4 Support: |
1= 100BASE-T4 is supported by the local device. | |||
0 = 100BASE-T4 not supported. | |||
8 | TX_FD | Strap, RW | 100BASE-TX Full Duplex Support: |
1 = 100BASE-TX Full Duplex is supported by the local device. | |||
0 = 100BASE-TX Full Duplex not supported. | |||
7 | TX | Strap, RW | 100BASE-TX Support: |
1 = 100BASE-TX is supported by the local device. | |||
0 = 100BASE-TX not supported. | |||
6 | 10_FD | Strap, RW | 10BASE-T Full Duplex Support: |
1 = 10BASE-T Full Duplex is supported by the local device. | |||
0 = 10BASE-T Full Duplex not supported. | |||
5 | 10 | Strap, RW | 10BASE-T Support: |
1 = 10BASE-T is supported by the local device. | |||
0 = 10BASE-T not supported. | |||
4:0 | SELECTOR | <00001>, RW | Protocol Selection Bits: |
These bits contain the binary encoded protocol selector supported by this port. <00001> indicates that this device supports IEEE 802.3u. |
This register contains the advertised abilities of the Link Partner as received during Auto-Negotiation. The content changes after the successful auto-negotiation if Next-pages are supported.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15 | NP | 0, RO | Next Page Indication: |
0 = Link Partner does not desire Next Page Transfer. | |||
1 = Link Partner desires Next Page Transfer. | |||
14 | ACK | 0, RO | Acknowledge: |
1 = Link Partner acknowledges reception of the ability data word. | |||
0 = Not acknowledged. | |||
The Auto-Negotiation state machine will automatically control the this bit based on the incoming FLP bursts. | |||
13 | RF | 0, RO | Remote Fault: |
1 = Remote Fault indicated by Link Partner. | |||
0 = No Remote Fault indicated by Link Partner. | |||
12 | RESERVED | 0, RO | RESERVED for Future IEEE use: |
Write as 0, read as 0. | |||
11 | ASM_DIR | 0, RO | ASYMMETRIC PAUSE: |
1 = Asymmetric pause is supported by the Link Partner. | |||
0 = Asymmetric pause is not supported by the Link Partner. | |||
10 | PAUSE | 0, RO | PAUSE: |
1 = Pause function is supported by the Link Partner. | |||
0 = Pause function is not supported by the Link Partner. | |||
9 | T4 | 0, RO | 100BASE-T4 Support: |
1 = 100BASE-T4 is supported by the Link Partner. | |||
0 = 100BASE-T4 not supported by the Link Partner. | |||
8 | TX_FD | 0, RO | 100BASE-TX Full Duplex Support: |
1 = 100BASE-TX Full Duplex is supported by the Link Partner. | |||
0 = 100BASE-TX Full Duplex not supported by the Link Partner. | |||
7 | TX | 0, RO | 100BASE-TX Support: |
1 = 100BASE-TX is supported by the Link Partner. | |||
0 = 100BASE-TX not supported by the Link Partner. | |||
6 | 10_FD | 0, RO | 10BASE-T Full Duplex Support: |
1 = 10BASE-T Full Duplex is supported by the Link Partner. | |||
0 = 10BASE-T Full Duplex not supported by the Link Partner. | |||
5 | 10 | 0, RO | 10BASE-T Support: |
1 = 10BASE-T is supported by the Link Partner. | |||
0 = 10BASE-T not supported by the Link Partner. | |||
4:0 | SELECTOR | <0 0000>, RO | Protocol Selection Bits: |
Link Partners binary encoded protocol selector. |
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15 | NP | 0, RO | Next Page Indication: |
1 = Link Partner desires Next Page Transfer. | |||
0 = Link Partner does not desire Next Page Transfer. | |||
14 | ACK | 0, RO | Acknowledge: |
1 = Link Partner acknowledges reception of the ability data word. | |||
0 = Not acknowledged. | |||
The Auto-Negotiation state machine will automatically control the this bit based on the incoming FLP bursts. Software should not attempt to write to this bit. | |||
13 | MP | 0, RO | Message Page: |
1 = Message Page. | |||
0 = Unformatted Page. | |||
12 | ACK2 | 0, RO | Acknowledge 2: |
1 = Link Partner does have the ability to comply to next page message. | |||
0 = Link Partner does not have the ability to comply to next page message. | |||
11 | TOGGLE | 0, RO | Toggle: |
1 = Previous value of the transmitted Link Code word equalled 0. | |||
0 = Previous value of the transmitted Link Code word equalled 1. | |||
10:0 | CODE | <000 0000 0000>, RO | Code: |
This field represents the code field of the next page transmission. If the MP bit is set (bit 13 of this register), then the code shall be interpreted as a Message Page, as defined in annex 28C of Clause 28. Otherwise, the code shall be interpreted as an Unformatted Page, and the interpretation is application specific. |
This register contains additional Local Device and Link Partner status information.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15:5 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0. |
4 | 0, RO | Parallel Detection Fault: | |
1 = A fault has been detected via the Parallel Detection function. | |||
0 = A fault has not been detected. | |||
3 | LP_NP_ABLE | 0, RO | Link Partner Next Page Able: |
1 = Link Partner does support Next Page. | |||
0 = Link Partner does not support Next Page. | |||
2 | NP_ABLE | 1, RO/P | Next Page Able: |
1 = Indicates local device is able to send additional Next Pages. | |||
1 | PAGE_RX | 0, RO/COR | Link Code Word Page Received: |
1 = Link Code Word has been received, cleared on a read. | |||
0 = Link Code Word has not been received. | |||
0 | LP_AN_ABLE | 0, RO | Link Partner Auto-Negotiation Able: |
1 = indicates that the Link Partner supports Auto-Negotiation. | |||
0 = indicates that the Link Partner does not support Auto-Negotiation. |
This register contains the next page information sent by this device to its Link Partner during Auto-Negotiation.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15 | NP | 0, RW | Next Page Indication: |
0 = No other Next Page Transfer desired. | |||
1 = Another Next Page desired. | |||
14 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0. |
13 | MP | 1, RW | Message Page: |
1 = Message Page. | |||
0 = Unformatted Page. | |||
12 | ACK2 | 0, RW | Acknowledge2: |
1 = Will comply with message. | |||
0 = Cannot comply with message. | |||
Acknowledge2 is used by the next page function to indicate that Local Device has the ability to comply with the message received. | |||
11 | TOG_TX | 0, RO | Toggle: |
1 = Value of toggle bit in previously transmitted Link Code Word was 0. | |||
0 = Value of toggle bit in previously transmitted Link Code Word was 1. | |||
Toggle is used by the Arbitration function within Auto-Negotiation to ensure synchronization with the Link Partner during Next Page exchange. This bit shall always take the opposite value of the Toggle bit in the previously exchanged Link Code Word. | |||
10:0 | CODE | <000 0000 0001>, RW | Code: |
This field represents the code field of the next page transmission. If the MP bit is set (bit 13 of this register), then the code shall be interpreted as a "Message Page”, as defined in annex 28C of IEEE 802.3u. Otherwise, the code shall be interpreted as an "Unformatted Page”, and the interpretation is application specific. | |||
The default value of the CODE represents a Null Page as defined in Annex 28C of IEEE 802.3u. |
This register provides a single location within the register set for quick access to commonly accessed information.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0. |
14 | MDIX MODE | 0, RO | MDIX mode as reported by the Auto-Negotiation logic: |
This bit will be affected by the settings of the MDIX_EN and FORCE_MDIX bits in the PHYCR register. When MDIX is enabled, but not forced, this bit will update dynamically as the Auto-MDIX algorithm swaps between MDI and MDIX configurations. | |||
1 = MDI pairs swapped | |||
(Receive on TPTD pair, Transmit on TPRD pair) | |||
0 = MDI pairs normal | |||
(Receive on TRD pair, Transmit on TPTD pair) | |||
13 | RECEIVE ERROR LATCH | 0, RO/LH | Receive Error Latch: |
This bit will be cleared upon a read of the RECR register. | |||
1 = Receive error event has occurred since last read of RXERCNT (address 15h, Page 0). | |||
0 = No receive error event has occurred. | |||
12 | POLARITY STATUS | 0, RO | Polarity Status: |
This bit is a duplication of bit 4 in the 10BTSCR register. This bit will be cleared upon a read of the 10BTSCR register, but not upon a read of the PHYSTS register. | |||
1 = Inverted Polarity detected. | |||
0 = Correct Polarity detected. | |||
11 | FALSE CARRIER SENSE LATCH | 0, RO/LH | False Carrier Sense Latch: |
This bit will be cleared upon a read of the FCSR register. | |||
1 = False Carrier event has occurred since last read of FCSCR (address 14h). | |||
0 = No False Carrier event has occurred. | |||
10 | SIGNAL DETECT | 0, RO/LL | 100Base-TX qualified Signal Detect from PMA: |
This is the SD that goes into the link monitor. It is the AND of raw SD and descrambler lock, when address 16h, bit 8 (page 0) is set. When this bit is cleared, it will be equivalent to the raw SD from the PMD. | |||
9 | DESCRAMBLER LOCK | 0, RO/LL | 100Base-TX Descrambler Lock from PMD. |
8 | PAGE RECEIVED | 0, RO | Link Code Word Page Received: |
This is a duplicate of the Page Received bit in the ANER register, but this bit will not be cleared upon a read of the PHYSTS register. | |||
1 = A new Link Code Word Page has been received. Cleared on read of the ANER (address 06h, bit 1). | |||
0 = Link Code Word Page has not been received. | |||
7 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0. |
6 | REMOTE FAULT | 0, RO | Remote Fault: |
1 = Remote Fault condition detected (cleared on read of BMSR (address 01h) register or by reset). Fault criteria: notification from Link Partner of Remote Fault via Auto-Negotiation. | |||
0 = No remote fault condition detected. | |||
5 | JABBER DETECT | 0, RO | Jabber Detect: This bit only has meaning in 10 Mb/s mode. |
This bit is a duplicate of the Jabber Detect bit in the BMSR register, except that it is not cleared upon a read of the PHYSTS register. | |||
1 = Jabber condition detected. | |||
0 = No Jabber. | |||
4 | AUTO-NEG COMPLETE | 0, RO | Auto-Negotiation Complete: |
1 = Auto-Negotiation complete. | |||
0 = Auto-Negotiation not complete. | |||
3 | LOOPBACK STATUS | 0, RO | Loopback: |
1 = Loopback enabled. | |||
0 = Normal operation. | |||
2 | DUPLEX STATUS | 0, RO | Duplex: |
This bit indicates duplex status and is determined from Auto-Negotiation or Forced Modes. | |||
1 = Full duplex mode. | |||
0 = Half duplex mode. | |||
Note: This bit is only valid if Auto-Negotiation is enabled and complete and there is a valid link or if Auto-Negotiation is disabled and there is a valid link. | |||
1 | SPEED STATUS | 0, RO | Speed10: |
This bit indicates the status of the speed and is determined from Auto-Negotiation or Forced Modes. | |||
1 = 10 Mb/s mode. | |||
0 = 100 Mb/s mode. | |||
Note: This bit is only valid if Auto-Negotiation is enabled and complete and there is a valid link or if Auto-Negotiation is disabled and there is a valid link. | |||
0 | LINK STATUS | 0, RO | Link Status: |
This bit is a duplicate of the Link Status bit in the BMSR register, except that it will not be cleared upon a read of the PHYSTS register. | |||
1 = Valid link established (for either 10 or 100 Mb/s operation). | |||
0 = Link not established. |
This counter provides information required to implement the “False Carriers” attribute within the MAU managed object class of Clause 30 of the IEEE 802.3u specification.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15:8 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0 |
7:0 | FCSCNT[7:0] | 0, RO/COR | False Carrier Event Counter: |
This 8-bit counter increments on every false carrier event. This counter sticks when it reaches its max count (FFh). |
This counter provides information required to implement the “Symbol Error During Carrier” attribute within the PHY managed object class of Clause 30 of the IEEE 802.3u specification.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15:8 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0. |
7:0 | RXERCNT[7:0] | 0, RO/COR | RX_ER Counter: |
When a valid carrier is present and there is at least one occurrence of an invalid data symbol, this 8-bit counter increments for each receive error detected. This event can increment only once per valid carrier event. If a collision is present, the attribute will not increment. The counter sticks when it reaches its max count. |
This register contains control and status information for the 100BASE Physical Coding Sublayer.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15:13 | RESERVED | <00>, RO | RESERVED: Writes ignored, read as 0. |
12 | RESERVED | 0 | RESERVED:Must be zero. |
11 | FREE_CLK | 0, RW | Receive Clock: |
10 | TQ_EN | 0, RW | 100Mbs True Quiet Mode Enable: |
1 = Transmit True Quiet Mode. | |||
0 = Normal Transmit Mode. | |||
9 | SD FORCE PMA | 0, RW | Signal Detect Force PMA: |
1 = Forces Signal Detection in PMA. | |||
0 = Normal SD operation. | |||
8 | SD_OPTION | 1, RW | Signal Detect Option: |
1 = Default operation. Link will be asserted following detection of valid signal level and Descrambler Lock. Link will be maintained as long as signal level is valid. A loss of Descrambler Lock will not cause Link Status to drop. | |||
0 = Modified signal detect algorithm. Link will be asserted following detection of valid signal level and Descrambler Lock. Link will be maintained as long as signal level is valid and Descrambler remains locked. | |||
7 | DESC_TIME | 0, RW | Descrambler Timeout: |
Increase the descrambler timeout. When set this should allow the device to receive larger packets (>9k bytes) without loss of synchronization. | |||
1 = 2ms. | |||
0 = 722us (per ANSI X3.263: 1995 (TP-PMD) 7.2.3.3e). | |||
6 | RESERVED | 0 | RESERVED: Must be zero. |
5 | FORCE_100_OK | 0, RW | Force 100 Mb/s Good Link: |
1 = Forces 100 Mb/s Good Link. | |||
0 = Normal 100 Mb/s operation. | |||
4 | RESERVED | 0 | RESERVED:Must be zero. |
3 | RESERVED | 0 | RESERVED:Must be zero. |
2 | NRZI_BYPASS | 0, RW | NRZI Bypass Enable: |
1 = NRZI Bypass Enabled. | |||
0 = NRZI Bypass Disabled. | |||
1 | RESERVED | 0 | RESERVED:Must be zero. |
0 | RESERVED | 0 | RESERVED:Must be zero. |
This register configures the RMII Mode of operation. When RMII mode is disabled, the RMII functionality is bypassed.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15:6 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0. |
5 | RMII_MODE | Strap, RW | Reduced MII Mode: |
0 = Standard MII Mode. | |||
1 = Reduced MII Mode. | |||
4 | RMII_REV1_0 | 0, RW | Reduced MII Revision 1.0: |
0 = (RMII revision 1.2) CRS_DV will toggle at the end of a packet to indicate deassertion of CRS. | |||
1 = (RMII revision 1.0) CRS_DV will remain asserted until final data is transferred. CRS_DV will not toggle at the end of a packet. | |||
3 | RX_OVF_STS | 0, RO | RX FIFO Over Flow Status: |
0 = Normal. | |||
1 = Overflow detected. | |||
2 | RX_UNF_STS | 0, RO | RX FIFO Under Flow Status: |
0 = Normal. | |||
1 = Underflow detected. | |||
1:0 | ELAST_BUF[1:0] | 01, RW | Receive Elasticity Buffer: |
This field controls the Receive Elasticity Buffer which allows for frequency variation tolerance between the 50 MHz RMII clock and the recovered data. The following values indicate the tolerance in bits for a single packet. The minimum setting allows for standard Ethernet frame sizes at +/-50ppm accuracy for both RMII and Receive clocks. For greater frequency tolerance the packet lengths may be scaled (i.e. for +/-100ppm, the packet lenths need to be divided by 2). | |||
00 = 14 bit tolerance (up to 16800 byte packets) | |||
01 = 2bit tolerance (up to 2400 byte packets) | |||
10 = 6bit tolerance (up to 7200 byte packets) | |||
11 = 10 bit tolerance (up to 12000 byte packets) |
This register provides the ability to directly control the LED output. It does not provide read access to the LED.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15:5 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0. |
4 | DRV_LNKLED | 0, RW | 1 = Drive value of LNKLED bit onto LED_LINK output. |
0 = Normal operation. | |||
3:2 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0. Value to force on LED_LINK output. |
1 | LNKLED | 0, RW | Value to force on LED_LINK output. |
0 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0. |
This register provides control for Phy functions such as MDIX, BIST, LED configuration, and Phy address. It also provides Pause Negotiation status.
BIT | BIT NAME | DEFAULT | DESCRIPTION | |
---|---|---|---|---|
15 | MDIX_EN | Strap, RW | Auto-MDIX Enable: | |
1 = Enable Auto-neg Auto-MDIX capability. | ||||
0 = Disable Auto-neg Auto-MDIX capability. | ||||
The Auto-MDIX algorithm requires that the Auto-Negotiation Enable bit in the BMCR register to be set. If Auto-Negotiation is not enabled, Auto-MDIX should be disabled as well. | ||||
14 | FORCE_MDIX | 0, RW | Force MDIX: | |
1 = Force MDI pairs to cross. | ||||
(Receive on TPTD pair, Transmit on TPRD pair) | ||||
0 = Normal operation. | ||||
13 | PAUSE_RX | 0, RO | Pause Receive Negotiated: | |
Indicates that pause receive should be enabled in the MAC. Based on ANAR[11:10] and ANLPAR[11:10] settings. | ||||
This function shall be enabled according to IEEE 802.3 Annex 28B Table 28B-3, “Pause Resolution”, only if the Auto-Negotiated Highest Common Denominator is a full duplex technology. | ||||
12 | PAUSE_TX | 0, RO | Pause Transmit Negotiated: | |
Indicates that pause transmit should be enabled in the MAC. Based on ANAR[11:10] and ANLPAR[11:10] settings. | ||||
This function shall be enabled according to IEEE 802.3 Annex 28B Table 28B-3, Pause Resolution, only if the Auto-Negotiated Highest Common Denominator is a full duplex technology. | ||||
11 | BIST_FE | 0, RW/SC | BIST Force Error: | |
1 = Force BIST Error. | ||||
0 = Normal operation. | ||||
This bit forces a single error, and is self clearing. | ||||
10 | PSR_15 | 0, RW | BIST Sequence select: | |
1 = PSR15 selected. | ||||
0 = PSR9 selected. | ||||
9 | BIST_STATUS | 0, LL/RO | BIST Test Status: | |
1 = BIST pass. | ||||
0 = BIST fail. Latched, cleared when BIST is stopped. | ||||
For a count number of BIST errors, see the BIST Error Count in the Table 5-26. | ||||
8 | BIST_START | 0, RW | BIST Start: | |
1 = BIST start. | ||||
0 = BIST stop. | ||||
7 | BP_STRETCH | 0, RW | Bypass LED Stretching: | |
This will bypass the LED stretching and the LED will reflect the internal value. | ||||
1 = Bypass LED stretching. | ||||
0 = Normal operation. | ||||
6 | RESERVED | 0, RO | RESERVED: Writes ignored, read as 0. | |
5 | LED_CFG | Strap, RW | LED Configuration | |
LED_CFG | Mode Description | |||
1 | Mode 1 | |||
0 | Mode 2 | |||
In Mode 1, LED is configured as follows: LED_LINK = ON for Good Link, OFF for No Link |
||||
In Mode 2, LED is configured as follows: LED_LINK = ON for good Link, BLINK for Activity |
||||
4:0 | PHYADDR[4:0] | Strap, RW | PHY Address: PHY address for port. |
This register is used for control and status for 10BASE-T device operation.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15:12 | RESERVED | 0, RW | RESERVED: Must be zero. |
11:9 | SQUELCH | 100, RW | Squelch Configuration:
Used to set the Squelch ON threshold for the receiver. Default Squelch ON is 330mV peak. |
8 | LOOPBACK_10_DIS | 0, RW | 10Base-T Loopback Disable: |
In half-duplex mode, default 10BASE-T operation loops Transmit data to the Receive data in addition to transmitting the data on the physical medium. This is for consistency with earlier 10BASE2 and 10BASE5 implementations which used a shared medium. Setting this bit disables the loopback function. | |||
This bit does not affect loopback due to setting BMCR[14]. | |||
7 | LP_DIS | 0, RW | Normal Link Pulse Disable: |
1 = Transmission of NLPs is disabled. | |||
0 = Transmission of NLPs is enabled. | |||
6 | FORCE_LINK_10 | 0, RW | Force 10Mb Good Link: |
1 = Forced Good 10Mb Link. | |||
0 = Normal Link Status. | |||
5 | RESERVED | 0, RW | RESERVED: Must be zero. |
4 | POLARITY | RO/LH | 10Mb Polarity Status: |
This bit is a duplication of bit 12 in the PHYSTS register. Both bits will be cleared upon a read of 10BTSCR register, but not upon a read of the PHYSTS register. | |||
1 = Inverted Polarity detected. | |||
0 = Correct Polarity detected. | |||
3 | RESERVED | 0, RW | RESERVED: Must be zero. |
2 | RESERVED | 1, RW | RESERVED: Must be set to one. |
1 | HEARTBEAT_DIS | 0, RW | Heartbeat Disable: This bit only has influence in half-duplex 10Mb mode. |
1 = Heartbeat function disabled. | |||
0 = Heartbeat function enabled. | |||
When the device is operating at 100Mb or configured for full duplex operation, this bit will be ignored - the heartbeat function is disabled. | |||
0 | JABBER_DIS | 0, RW | Jabber Disable: |
Applicable only in 10BASE-T. | |||
1 = Jabber function disabled. | |||
0 = Jabber function enabled. |
This register controls test modes for the 10BASE-T Common Driver. In addition it contains extended control and status for the packet BIST function.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15:8 | BIST_ERROR_COUNT | 0, RO | BIST ERROR Counter: |
Counts number of errored data nibbles during Packet BIST. This value will reset when Packet BIST is restarted. The counter sticks when it reaches its max count. | |||
7:6 | RESERVED | 0, RW | RESERVED: Must be zero. |
5 | BIST_CONT_MODE | 0, RW | Packet BIST Continuous Mode: |
Allows continuous pseudo random data transmission without any break in transmission. This can be used for transmit VOD testing. This is used in conjunction with the BIST controls in the PHYCR Register (19h). For 10Mb operation, jabber function must be disabled, bit 0 of the 10BTSCR (1Ah), JABBER_DIS = 1. | |||
4 | CDPATTEN_10 | 0, RW | CD Pattern Enable for 10Mb: |
1 = Enabled. | |||
0 = Disabled. | |||
3 | RESERVED | 0, RW | RESERVED: Must be zero. |
2 | 10MEG_PATT_GAP | 0, RW | Defines gap between data or NLP test sequences: |
1 = 15 µs. | |||
0 = 10 µs. | |||
1:0 | CDPATTSEL[1:0] | 00, RW | CD Pattern Select[1:0]: |
If CDPATTEN_10 = 1: | |||
00 = Data, EOP0 sequence. | |||
01 = Data, EOP1 sequence. | |||
10 = NLPs. | |||
11 = Constant Manchester 1s (10 MHz sine wave) for harmonic distortion testing. |
This register provides control and status for the Energy Detect function.
BIT | BIT NAME | DEFAULT | DESCRIPTION |
---|---|---|---|
15 | ED_EN | 0, RW | Energy Detect Enable: |
Allow Energy Detect Mode. | |||
When Energy Detect is enabled and Auto-Negotiation is disabled via the BMCR register, Auto-MDIX should be disabled via the PHYCR register. | |||
14 | ED_AUTO_UP | 1, RW | Energy Detect Automatic Power Up: |
Automatically begin power up sequence when Energy Detect Data Threshold value (EDCR[3:0]) is reached. Alternatively, device could be powered up manually using the ED_MAN bit (ECDR[12]). | |||
13 | ED_AUTO_DOWN | 1, RW | Energy Detect Automatic Power Down: |
Automatically begin power down sequence when no energy is detected. Alternatively, device could be powered down using the ED_MAN bit (EDCR[12]). | |||
12 | ED_MAN | 0, RW/SC | Energy Detect Manual Power Up/Down: |
Begin power up/down sequence when this bit is asserted. When set, the Energy Detect algorithm will initiate a change of Energy Detect state regardless of threshold (error or data) and timer values. | |||
11 | ED_BURST_DIS | 0, RW | Energy Detect Burst Disable: |
Disable bursting of energy detect data pulses. By default, Energy Detect (ED) transmits a burst of 4 ED data pulses each time the CD is powered up. When bursting is disabled, only a single ED data pulse will be send each time the CD is powered up. | |||
10 | ED_PWR_STATE | 0, RO | Energy Detect Power State: |
Indicates current Energy Detect Power state. When set, Energy Detect is in the powered up state. When cleared, Energy Detect is in the powered down state. This bit is invalid when Energy Detect is not enabled. | |||
9 | ED_ERR_MET | 0, RO/COR | Energy Detect Error Threshold Met: |
No action is automatically taken upon receipt of error events. This bit is informational only and would be cleared on a read. | |||
8 | ED_DATA_MET | 0, RO/COR | Energy Detect Data Threshold Met: |
The number of data events that occurred met or surpassed the Energy Detect Data Threshold. This bit is cleared on a read. | |||
7:4 | ED_ERR_COUNT | 0001, RW | Energy Detect Error Threshold: |
Threshold to determine the number of energy detect error events that should cause the device to take action. Intended to allow averaging of noise that may be on the line. Counter will reset after approximately 2 seconds without any energy detect data events. | |||
3:0 | ED_DATA_COUNT | 0001, RW | Energy Detect Data Threshold: |
Threshold to determine the number of energy detect events that should cause the device to take actions. Intended to allow averaging of noise that may be on the line. Counter will reset after approximately 2 seconds without any energy detect data events. |