SLVSHE3 June 2024 DRV2911-Q1
PRODUCTION DATA
If the input supply voltage on the FB_BK pin falls lower than the VBK_UVLO threshold, all of both high-side and low-side MOSFETs of the buck regulator are disabled and the FAULTZ pin is driven low. Normal operation starts again (buck operation and the FAULTZ pin is released) when the VBK undervoltage condition clears.