SLIS162I December   2014  – February 2023 DRV5013-Q1

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
    7. 6.7 Magnetic Characteristics
    8. 6.8 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Field Direction Definition
      2. 7.3.2 Device Output
      3. 7.3.3 Power-On Time
      4. 7.3.4 Output Stage
      5. 7.3.5 Protection Circuits
        1. 7.3.5.1 Overcurrent Protection (OCP)
        2. 7.3.5.2 Load Dump Protection
        3. 7.3.5.3 Reverse Supply Protection
    4. 7.4 Device Functional Modes
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Applications
      1. 8.2.1 Standard Circuit
        1. 8.2.1.1 Design Requirements
        2. 8.2.1.2 Detailed Design Procedure
          1. 8.2.1.2.1 Configuration Example
        3. 8.2.1.3 Application Curves
      2. 8.2.2 Alternative Two-Wire Application
        1. 8.2.2.1 Design Requirements
        2. 8.2.2.2 Detailed Design Procedure
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  9. Device and Documentation Support
    1. 9.1 Device Support
      1. 9.1.1 Device Nomenclature
      2. 9.1.2 Device Markings
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  10. 10Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Magnetic Characteristics

over operating free-air temperature range (unless otherwise noted)
PARAMETERTEST CONDITIONSMINTYPMAXUNIT#SLIS1501447
ƒBWBandwidth#SLIS15036652030kHz
DRV5013FA: ±1.3 mT
BOPOperate point; see GUID-6863B19C-B9C2-4D6E-A73A-967CA48565A9.html#SLIS1508288–0.61.33.4mT
BRPRelease point; see GUID-6863B19C-B9C2-4D6E-A73A-967CA48565A9.html#SLIS1508288–3.4–1.30.6mT
BhysHysteresis; Bhys = (BOP – BRP)1.22.6mT
BOMagnetic offset; BO = (BOP + BRP) / 2–1.501.5mT
DRV5013AD: ±2.7 mT
BOPOperate point; see GUID-6863B19C-B9C2-4D6E-A73A-967CA48565A9.html#SLIS150828812.75mT
BRPRelease point; see GUID-6863B19C-B9C2-4D6E-A73A-967CA48565A9.html#SLIS1508288–5–2.7–1mT
BhysHysteresis; Bhys = (BOP – BRP)5.4mT
BOMagnetic offset; BO = (BOP + BRP) / 2–1.501.5mT
DRV5013AG: ±6 mT
BOPOperate point; see GUID-6863B19C-B9C2-4D6E-A73A-967CA48565A9.html#SLIS1508288369mT
BRPRelease point; see GUID-6863B19C-B9C2-4D6E-A73A-967CA48565A9.html#SLIS1508288–9–6–3mT
BhysHysteresis; Bhys = (BOP – BRP)12mT
BOMagnetic offset; BO = (BOP + BRP) / 2–1.501.5mT
DRV5013BC: ±12 mT
BOPOperate point; see GUID-6863B19C-B9C2-4D6E-A73A-967CA48565A9.html#SLIS150828861218mT
BRPRelease point; see GUID-6863B19C-B9C2-4D6E-A73A-967CA48565A9.html#SLIS1508288–18–12–6mT
BhysHysteresis; Bhys = (BOP – BRP)24mT
BOMagnetic offset; BO = (BOP + BRP) / 2–1.501.5mT
1 mT = 10 Gauss.
Bandwidth describes the fastest changing magnetic field that can be detected and translated to the output.