SLVSH04 November   2023 DRV8214

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Revision History
  6. Device Comparison
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 I2C Timing Requirements
    7. 7.7 Timing Diagrams
    8. 7.8 Typical Operating Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 External Components
      2. 8.3.2 Summary of Features
      3. 8.3.3 Bridge Control
      4. 8.3.4 Current Sense and Regulation (IPROPI)
        1. 8.3.4.1 Current Sensing and Current Mirror Gain Selection
        2. 8.3.4.2 Current Regulation
          1. 8.3.4.2.1 Fixed Off-Time Current Regulation
          2. 8.3.4.2.2 Cycle-By-Cycle Current Regulation
      5. 8.3.5 Stall Detection
      6. 8.3.6 Ripple Counting
        1. 8.3.6.1 Ripple Counting Parameters
          1. 8.3.6.1.1  Motor Resistance Inverse
          2. 8.3.6.1.2  Motor Resistance Inverse Scale
          3. 8.3.6.1.3  KMC Scaling Factor
          4. 8.3.6.1.4  KMC
          5. 8.3.6.1.5  Filter Damping Constant
          6. 8.3.6.1.6  Filter Input Scaling Factor
          7. 8.3.6.1.7  Ripple Count Threshold
          8. 8.3.6.1.8  Ripple Count Threshold Scale
          9. 8.3.6.1.9  T_MECH_FLT
          10. 8.3.6.1.10 VSNS_SEL
          11. 8.3.6.1.11 Error Correction
            1. 8.3.6.1.11.1 EC_FALSE_PER
            2. 8.3.6.1.11.2 EC_MISS_PER
        2. 8.3.6.2 RC_OUT Output
        3. 8.3.6.3 Ripple Counting with nFAULT
      7. 8.3.7 Motor Voltage and Speed Regulation
        1. 8.3.7.1 Internal Bridge Control
        2. 8.3.7.2 Setting Speed/Voltage Regulation Parameters
          1. 8.3.7.2.1 Speed and Voltage Set
          2. 8.3.7.2.2 Speed Scaling Factor
        3. 8.3.7.3 Soft-Start and Soft-Stop
          1. 8.3.7.3.1 TINRUSH
      8. 8.3.8 Protection Circuits
        1. 8.3.8.1 Overcurrent Protection (OCP)
        2. 8.3.8.2 Thermal Shutdown (TSD)
        3. 8.3.8.3 VCC Undervoltage Lockout (UVLO)
        4. 8.3.8.4 Overvoltage Protection (OVP)
        5. 8.3.8.5 nFAULT Output
    4. 8.4 Device Functional Modes
      1. 8.4.1 Active Mode
      2. 8.4.2 Low-Power Sleep Mode
      3. 8.4.3 Fault Mode
    5. 8.5 Programming
      1. 8.5.1 I2C Communication
        1. 8.5.1.1 I2C Write
        2. 8.5.1.2 I2C Read
    6. 8.6 Register Map
      1. 8.6.1 DRV8214_STATUS Registers
      2. 8.6.2 DRV8214_CONFIG Registers
      3. 8.6.3 DRV8214_CTRL Registers
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application: Brushed DC Motor
      1. 9.2.1 Design Requirements
      2. 9.2.2 Stall Detection
        1. 9.2.2.1 Application Description
          1. 9.2.2.1.1 Stall Detection Timing
          2. 9.2.2.1.2 Hardware Stall Threshold Selection
      3. 9.2.3 Ripple Counting Application
        1. 9.2.3.1 Tuning Ripple Counting Parameters
          1. 9.2.3.1.1 Resistance Parameters
          2. 9.2.3.1.2 KMC and KMC_SCALE
            1. 9.2.3.1.2.1 Case I
            2. 9.2.3.1.2.2 Case II
              1. 9.2.3.1.2.2.1 Method 1: Tuning from Scratch
                1. 9.2.3.1.2.2.1.1 Tuning KMC_SCALE
                2. 9.2.3.1.2.2.1.2 Tuning KMC
              2. 9.2.3.1.2.2.2 Method 2: Using the Proportionality factor
                1. 9.2.3.1.2.2.2.1 Working Example
          3. 9.2.3.1.3 Advanced Parameters
            1. 9.2.3.1.3.1 Filter Constants
              1. 9.2.3.1.3.1.1 FLT_GAIN_SEL
              2. 9.2.3.1.3.1.2 FLT_K
            2. 9.2.3.1.3.2 T_MECH_FLT
            3. 9.2.3.1.3.3 VSNS_SEL
            4. 9.2.3.1.3.4 Additional Error Corrector Parameters
              1. 9.2.3.1.3.4.1 EC_FALSE_PER
              2. 9.2.3.1.3.4.2 EC_MISS_PER
      4. 9.2.4 Motor Voltage
      5. 9.2.5 Motor Current
      6. 9.2.6 Application Curves
  11. 10Power Supply Recommendations
    1. 10.1 Bulk Capacitance
  12. 11Layout
    1. 11.1 Layout Guidelines
  13. 12Mechanical, Packaging, and Orderable Information
    1. 12.1 Tape and Reel Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information
FLT_K

Denoted by FLT_K, this parameter represents the quality factor or Q-factor of the band pass filter. Tune this parameter to increase or decrease the bandwidth to accommodate a wider or narrower range of ripple frequencies around the center frequency. Center frequency of the filter is based on the frequency estimation of the motor for the ripples.

Settings are shown in Table 9-5. Recommended value is the default value: 0110b.

Table 9-5 Settings for FLT_K
Bit Decimal Value
0000 0 0.007813
0001 1 0.015265
0010 2 0.03125
0011 3 0.0625
0100 4 0.125
0101 5 0.25
0110 6 0.5
0111 7 0.625
1000 8 0.75
1001 9 0.825
1010 - 1111 10-15 1