SLVSFG5D September 2020 – March 2022 DRV8300
PRODUCTION DATA
The DRV8300 is in operating (active) mode, whenever the GVDD and BST pins are higher than the UV threshold (GVDD > VGVDDUVand VBSTX > VBSTUV). In active mode, the gate driver output GHx and GLX will follow respective inputs INHx and INLx.