SLOSEC6 August 2024 DRV8434A-Q1
PRODUCTION DATA
An analog current-limit circuit on each MOSFET limits the current through the MOSFET by removing the gate drive. If this current limit persists for longer than the tOCP time, the MOSFETs in both H-bridges are disabled and the nFAULT pin is driven low. The charge pump remains active during this condition. Normal operation resumes automatically (motor-driver operation and nFAULT released) after the tRETRY time has elapsed and the fault condition is removed.