TBLANK_TIME |
Blanking Time |
---|---|
00b |
1 μs |
01b (default) |
1.5 μs |
10b |
2 μs |
11b |
2.5 μs |
When the current is close to the ITRIP level, a 0.5 μs deglitch time ensures proper current regulation.