SLOSE98A December 2022 – September 2023 DRV8461
PRODUCTION DATA
FAULT | CONDITION | CONFIGURATION | ERROR REPORT | H-BRIDGE | CHARGE PUMP | INDEXER | LOGIC | RECOVERY |
---|---|---|---|---|---|---|---|---|
VM undervoltage (UVLO) | VM < VUVLO | — | nFAULT / SPI | Disabled | Disabled | Disabled | Reset | VM > VUVLO |
VCP undervoltage (CPUV) | VCP < VCPUV | — | nFAULT / SPI | Disabled | Operating | Operating | Operating | VCP > VCPUV |
Logic Supply POR | VCC < VCCUVLO | — | SPI | Disabled | Disabled | Disbaled | Reset | VCC > VCCUVLO |
Overcurrent (OCP) | IOUT > IOCP | OCP_MODE = 0b / ENABLE = Hi-Z | nFAULT / SPI | Disabled | Operating | Operating | Operating | Latched: CLR_FLT / nSLEEP reset pulse |
OCP_MODE = 1b / ENABLE = 1 | nFAULT / SPI | Disabled | Operating | Operating | Operating | Automatic retry: tRETRY | ||
Open Load (OL) | No load detected | OL_MODE = 1b / ENABLE = 1 | nFAULT / SPI | Operating | Operating | Operating | Operating | Automatic |
OL_MODE = 0b / ENABLE = Hi-Z | nFAULT / SPI | Operating | Operating | Operating | Operating | Latched: CLR_FLT / nSLEEP reset pulse | ||
Stall Detection (STALL) | Stall / stuck motor | STL_REP = 0b | SPI | Operating | Operating | Operating | Operating | CLR_FLT / nSLEEP reset pulse |
STL_REP = 1b | nFAULT / SPI | Operating | Operating | Operating | Operating | |||
Overtemperature Warning (OTW) | TJ > TOTW | TW_REP = 1b | nFAULT / SPI | Operating | Operating | Operating | Operating | Automatic: TJ < TOTW - THYS_OTW |
TW_REP = 0b | SPI | Operating | Operating | Operating | Operating | |||
Thermal Shutdown (OTSD) | TJ > TOTSD | OTSD_MODE = 0b / ENABLE = Hi-Z | nFAULT / SPI | Disabled | Disabled | Operating | Operating | Latched: CLR_FLT / nSLEEP reset pulse |
OTSD_MODE = 1b / ENABLE = 1 | nFAULT/ SPI | Disabled | Disabled | Operating | Operating | Automatic: TJ < TOTSD - THYS_OTSD |